This study evaluates the performance of single concrete-filled frictional Fibre-Reinforced Polymer (FRP) piles embedded in saturated liquefiable sand and subjected to seismic loading using a shaking table. A unidirectional shaking table equipped with a 1000 mm × 1000 mm × 1000 mm laminar shear box with 27 lamina rings was utilized in the study. FRP tubes manufactured from epoxy-saturated Carbon Fibre-Reinforced Polymer (CFRP) and Glass Fibre-Reinforced Polymer (GFRP) fabrics were filled with 35 MPa concrete and allowed to cure for 28 days, serving as model piles for the experimental programme, with cylindrical concrete prisms employed to represent the behaviour of traditional piles. Pile dimensions and properties based on scaling relationships were selected to account for the nonlinear nature of soil–pile systems under seismic loading. Scaled versions of ground motions from the 2010 Val-des-Bois and 1995 Hyogo-Ken Nambu earthquakes were implemented as input motions in the tests. The results show limited variation in the inertial and kinematic responses of the piles, especially before liquefaction. Head rocking displacements were within 5% of each other during liquefaction. Post liquefaction, the concrete-filled FRP piles showed lower response compared to the traditional concrete pile. The results suggests that concrete-filled FRP piles, especially those made from carbon fibre, provide practical alternatives for use.
Abdul-Hamid et al. (Mon,) studied this question.