This study addresses the impact-induced failure of drilling pump valves caused by uncontrolled disc–seat collisions by proposing a novel valve design incorporating a two-stage buffering mechanism. The design employs a wave spring as the primary buffer and an elastic sealing ring as the secondary buffer, effectively mitigating impact through staged energy dissipation. A nonlinear stiffness model of the wave spring, accounting for the transition between line and surface contact modes, was developed. Strong fluid–structure interaction transients were simulated using dynamic meshing and user-defined functions. A parametric study was conducted by systematically varying cylindrical spring stiffness (7.7–15 N/mm), preload (110–160 N), and wave spring type (D85 to D110). Results show that, compared to a conventional valve, the two-stage mechanism reduces impact velocity by 24.2%, accelerates opening response by 17.9%, and extends the closing phase by 0.28%. Increasing wave spring stiffness (from D85 to D110) decreases opening delay time by 98.7% and attenuates peak velocity by 44.4%. Optimized hybrid spring parameters can minimize closing delay height by 27.3%. By reducing seat erosion and suppressing vibration-induced failure, the two-stage buffering mechanism effectively extends valve service life and enhances operational reliability in high-cycle drilling operations.
Wu et al. (Tue,) studied this question.