Reliable in situ temperature monitoring is essential for the safe operation of liquid-nitrogen-cooled superconducting cables, yet conventional electrical sensors are often difficult to scale to multi-point deployment in cryogenic, high-current environments. This work presents a fiber Bragg grating (FBG) sensing solution for in situ temperature monitoring of superconducting cables in liquid nitrogen. An FBG array packaged with a polyimide-coated fiber inside a 3 mm stainless-steel tube is deployed along the cable centerline to provide multi-point temperature measurements of the cable core. The system is validated under liquid-nitrogen immersion with a 2000 A current turn-on/turn-off test, with a 1 Hz update rate and a steady-state temperature fluctuation within ±0.1 °C. Experimental results show a continuous temperature decrease during liquid-nitrogen cooling, followed by a cryogenic plateau, during which a spatially consistent 0.6–0.7 °C current-induced temperature rise is observed across multiple sensing points in the present 2000 A turn-on/turn-off test, followed by recovery after current shutoff. Small-amplitude fluctuations during the plateau are attributed to packaging-dependent thermal coupling between the centerline-deployed sensor and the cable core. These results indicate that the proposed FBG-based approach enables reliable cryogenic thermometry for superconducting cables in liquid nitrogen and provides a practical tool for in situ operational condition assessment.
Chen et al. (Fri,) studied this question.