As extreme-scale manufacturing evolves, the dynamic response of heavy moving components under ultra-high loads becomes a critical design challenge. This study focuses on friction-induced vibration of a more than 30-ton movable mass during the mold-opening stage in a two-platen machine with a clamping force >17,000 kN. A mathematical model and a validated rigid/flexible multibody dynamics model with PID co-simulation were developed to analyze transient vibration using maximum acceleration amplitude and stability time as core metrics. The results show vibration stems from imbalance between anti-opening resistance and hydraulic driving force, amplified by vacuum collapse, static-to-dynamic friction transition at slide feet/rail interface and PID overshoot, featuring high amplitude density (>0.75 g), transience (60,000 N). The maximum vibration acceleration amplitude remains 79.22% even after there is no mold vacuum suction, indicating that a static friction force other than the vacuum suction is the dominant factor resulting in a severe friction-induced vibration. These mechanistic insights establish an applicable framework for the dynamic optimization of the heavy components in extreme-large-scale manufacturing equipment.
Chen et al. (Tue,) studied this question.