February 22, 2026NMR in Biomedicine0 citationsOpen Access

31 P‐MRS of the Human Heart at 7 T With an Integrated Whole‐Body 31 P Radiofrequency Transmit Coil

View Full Paper
MGM. GosselinkFMFroeling MartijnKVKathy Verkerk

Key Points

  • To assess myocardial energy status using 31P-MRS at 7 T with improved precision for potential therapeutic monitoring.
  • Utilized integrated whole-body RF transmit coil for 31P spin excitation.
  • Conducted 31P-MRS on eight volunteers using a 20-mm isotropic resolution.
  • Employed a low-flip angle, short-repetition time 3D imaging sequence.
  • Quantified PCr, PDE, and Pi signals relative to ATP.
  • Performed Bland–Altman analyses to evaluate measurement repeatability.
  • Mid-septal myocardial PCr/ATP ratio was 1.85 ± 0.37.
  • Achieved a repeatability coefficient of 17.7% for PCr/ATP.
  • Found repeatability coefficients for Pi/ATP and PDE/ATP as 142.7% and 51.6%, respectively.
  • Demonstrated improved precision over previous lower magnetic field studies.

Abstract

ABSTRACT Phosphorus‐31 magnetic resonance spectroscopy ( 31 P‐MRS) can be used to characterize the steady‐state in vivo myocardial energy status via the phosphocreatine (PCr) over adenosine triphosphate (ATP) tissue concentration ratio. Although used in many studies, this modality suffers from low sensitivity and poor measurement precision. This work reports on the acquisition of 31 P‐MR spectra of the in vivo human heart using a 7 T MR system equipped with an integrated whole‐body RF transmit coil for 31 P spin excitation. Eight volunteers (male/female, n = 4/4) underwent 31 P‐MRS at 7 T twice, using a low‐flip angle, short‐repetition time 3D 31 P‐MR spectroscopic imaging sequence with a 20‐mm isotropic resolution and a 21‐min acquisition time. A 16‐channel 31 P receive array was used for signal reception. Myocardial voxels were identified on transversal cine proton MR images. Signals of PCr, phosphodiesters (PDE), and inorganic phosphate (P i ) were quantified relative to ATP and corrected for partial saturation and blood signal contamination. Bland–Altman analyses were used to establish intersession measurement repeatability. A comparison of supine and prone positioning was made for two subjects, yielding similar results but superior comfort for lying supine. Mid‐septal myocardial PCr/ATP was 1.85 ± 0.37, with a repeatability coefficient of 17.7%. The repeatability coefficients for P i /ATP and PDE/ATP were 142.7% and 51.6%, respectively. Using the spatially homogeneous 31 P spin excitation with the integrated whole‐body RF transmit coil, we made quantitative estimates of the myocardial energy status at a higher precision than previously achieved at lower main magnetic field strengths. The noninvasive nature and high precision of the presented 31 P‐MR spectroscopic imaging approach will allow for therapeutic efficacy monitoring with repeated measurements in longitudinal study designs and investigations of normal physiology in healthy volunteers.