Broadband Impedance Matching for Immersed CMUTs: An End-to-End Design-to-Measurement Validation Framework

View Full Paper
GGGabriel GuerreiroMAMartin AngererECEdmond Cretu

Key Points

  • This research aims to develop and validate a framework for designing effective impedance matching networks for CMUTs to improve their acoustic performance.
  • Developed an end-to-end measurement-driven experimental validation strategy.
  • Synthesize matching topologies to operate near the Bode-Fano limit.
  • Conducted Monte Carlo yield analysis for component tolerances.
  • Implemented and validated matching networks under unipolar pulse excitation.
  • Characterized far-field acoustic pressure in time and frequency domains.
  • Increased transmit power by a factor of 2.1.
  • Achieved a 40% reduction in fractional bandwidth.
  • Validated framework shows applicability in ultrasound imaging and therapeutic systems.

Abstract

Capacitive micromachined ultrasonic transducers (CMUTs) are a promising alternative to conventional piezoelectric transducers, offering superior design flexibility and broadband operational characteristics. However, their clinical and practical deployment is constrained by elevated driving voltages and limited acoustic power output, particularly when producing CMUTs based on polymers. This paper presents an end-to-end, measurement-driven experimental validation strategy for designing passive broadband impedance-matching networks that enhance transmitted acoustic power in immersed CMUT arrays while preserving bandwidth. Matching topologies are synthesized to operate near the theoretical Bode–Fano limit, and robustness to component tolerances is quantified through Monte Carlo yield analysis using realistic off-the-shelf component variations. The matching networks are then implemented and experimentally validated under representative unipolar pulse excitation, with far-field acoustic pressure characterized in both time and frequency domains and compared against numerical predictions. The results show that the optimized impedance matching increases transmit power by a factor of 2.1 at the cost of a 40% fractional-bandwidth reduction. These findings establish a directly applicable, validated framework for broadband impedance matching in polymer CMUT arrays and support its use as a cost-effective approach for ultrasound imaging and therapeutic systems.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Guerreiro et al. (2026) studied this question.

synapsesocial.com/papers/69a67efaf353c071a6f0aab6https://doi.org/10.3390/s26051546