PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 8, 2026European Stroke Journal0 citations

Abstract Number: Esoc2026a1783 Pilot in Vitro Study of Serial Double Stent Retrievers for Embolic Tandem Terminal Ica–m1 Occlusion

View Full Paper
YYYuki YamamotoAPAriel ParedesCMCristina Márquez

Key Points

  • This study aims to evaluate the effectiveness of a double stent retriever technique for treating tandem occlusions in the ICA and M1.
  • Tandem occlusions were created in an in vitro neurovascular model.
  • Clot analogs with varying red blood cell fractions were used in two conditions: soft and stiff consistency.
  • Two stent retrievers were deployed and retrieved in series alongside an aspiration catheter.
  • Technical success was achieved in all 14 pilot experiments.
  • The rate of first-pass complete reperfusion was higher with the double stent retriever technique (57%) compared to the single stent retriever technique (14%).
  • Further investigations in a larger randomized series are ongoing.

Abstract

Abstract Background and aims Embolic tandem occlusion involving the terminal internal carotid artery (ICA) and the M1 segment of the middle cerebral artery can create a large clot burden at separated sites, limiting first-pass reperfusion with a single stent retriever (SR). We evaluated a technique using two SRs deployed in series. Methods Tandem occlusions were created in an in vitro neurovascular model. Clot analogs with red blood cell fractions ranging from 25% to 90% were used and were allocated approximately 1:1 to soft and stiff consistency. In the double-SR technique, two SRs (6 × 40 mm in the ICA and 4 × 40 mm in M1) were deployed and retrieved simultaneously, whereas the single-SR technique used a one 4 × 40 mm SR in M1. Both techniques were performed with adjunct aspiration using a 0.071-inch aspiration catheter. Outcomes were procedural feasibility and the rate of first-pass complete reperfusion with no distal emboli ≥1 mm captured in the downstream filter. Results Fourteen pilot experiments were performed (double-SR, n = 7; single-SR, n = 7). Technical success was achieved in all cases. The rate of first-pass complete reperfusion was higher with double-SR than with single-SR (4/7 57% vs. 1/7 14%). Conclusions Serial double-SR retrieval appears technically feasible. The rate of first-pass complete reperfusion tended to be higher with double-SR than with single-SR. A larger randomized series (20 per group) is ongoing to clarify potential mechanical advantages of the double-SR strategy. Conflict of interest Yuki Yamamoto. nothing to disclose.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yamamoto et al. (2026) studied this question.

synapsesocial.com/papers/69fd7e42bfa21ec5bbf067c6https://doi.org/10.1093/esj/aakag023.836
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Magnetic Resonance Imaging-guided Double Stent Retriever Thrombectomy for Bifurcation Occlusions and Long Thrombi2025
  2. 2A Randomised Study Comparing First-line Dual Vs Single-Stentretriever Technique: TWIN2WIN2024
  3. 3New Stent Retriever Technology Versus Standard Devices for Anterior Large Vessel Thrombectomy: A Multicenter Study2025
  4. 4Impact of double stent retriever configuration on first-pass effect in stroke: a multicenter study2024 · 6 citations
  5. 5ABSTRACT NUMBER: ESOC2026A73 ENDOVASCULAR TREATMENT OF TANDEM OCCLUSIONS IN ANTERIOR CIRCULATION STROKE2026