PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 13, 2024European Journal of Nuclear Medicine and Molecular Imaging23 citationsOpen Access

Deep learning-aided respiratory motion compensation in PET/CT: addressing motion induced resolution loss, attenuation correction artifacts and PET-CT misalignment

View Full Paper
YLYihuan LuNovatek Microelectronics (Taiwan)FKFei KangZhengzhou UniversityDZDuo ZhangJilin University

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Purpose Respiratory motion (RM) significantly impacts image quality in thoracoabdominal PET/CT imaging. This study introduces a unified data-driven respiratory motion correction (uRMC) method, utilizing deep learning neural networks, to solve all the major issues caused by RM, i.e., PET resolution loss, attenuation correction artifacts, and PET-CT misalignment. Methods In a retrospective study, 737 patients underwent 18 FFDG PET/CT scans using the uMI Panorama PET/CT scanner. Ninety-nine patients, who also had respiration monitoring device (VSM), formed the validation set. The remaining data of the 638 patients were used to train neural networks used in the uRMC. The uRMC primarily consists of three key components: (1) data-driven respiratory signal extraction, (2) attenuation map generation, and (3) PET-CT alignment. SUV metrics were calculated within 906 lesions for three approaches, i.e., data-driven uRMC (proposed), VSM-based uRMC, and OSEM without motion correction (NMC). RM magnitude of major organs were estimated. Results uRMC enhanced diagnostic capabilities by revealing previously undetected lesions, sharpening lesion contours, increasing SUV values, and improving PET-CT alignment. Compared to NMC, uRMC showed increases of 10% and 17% in SUV max and SUV mean across 906 lesions. Sub-group analysis showed significant SUV increases in small and medium-sized lesions with uRMC. Minor differences were found between VSM-based and data-driven uRMC methods, with the SUV max was found statistically marginal significant or insignificant between the two methods. The study observed varied motion amplitudes in major organs, typically ranging from 10 to 20 mm. Conclusion A data-driven solution for respiratory motion in PET/CT has been developed, validated and evaluated. To the best of our knowledge, this is the first unified solution that compensates for the motion blur within PET, the attenuation mismatch artifacts caused by PET-CT misalignment, and the misalignment between PET and CT.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lu et al. (2024) studied this question.

synapsesocial.com/papers/68e5c751b6db64358755dbc0https://doi.org/10.1007/s00259-024-06872-x
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1PET/CT-Based Radiogenomics Supports KEAP1/NFE2L2 Pathway Targeting for Non–Small Cell Lung Cancer Treated with Curative Radiotherapy2024 · 9 citations
  2. 2Performance Evaluation of the uMI Panorama PET/CT System in Accordance with the National Electrical Manufacturers Association NU 2-2018 Standard2024 · 33 citations
  3. 3External respiratory motion analysis and statistics for patients and volunteers2013 · 48 citations
  4. 4A Review on Low-Dose Emission Tomography Post-Reconstruction Denoising With Neural Network Approaches2024 · 38 citations
  5. 5Registration-weighted motion correction for PET2012 · 10 citations