PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 18, 2026Journal of Thermal Science and Engineering Applications0 citations

Development and characterization of a sensitive NO measurement system by wavelength modulation spectroscopy for combustion and emission measurements

View Full Paper
SPSuhyeon ParkKTKyle ThurmondSVSubith Vasu

Key Points

  • This work aims to develop a sensitive measurement system for nitric oxides in combustion products using wavelength modulation spectroscopy.
  • Utilized mid-infrared wavelength modulation spectroscopy for NO measurement.
  • Selected the NO absorption line at 1939.61 cm−1 to minimize water interference.
  • Generated simulated absorption spectra for validation of the measurement line.
  • Implemented a WMS scheme to reject noise from various interference sources.
  • Conducted measurements under varying conditions using a flat flame burner.
  • Successfully quantified NO concentrations in combustion emissions.
  • Achieved a noise equivalent detection limit of 8.4 ppm-m for non-reacting flow.
  • Demonstrated the effectiveness of the measurement system under diverse flame conditions.

Abstract

Abstract Modern advanced power generation and propulsion systems realize the highest efficiency by achieving combustion reactions at higher temperatures and pressures. One of the challenges that comes with such harsh conditions is NOx emissions. A typical example can be found in combustors in gas turbines, and these need to be quantified. In this work, the concentrations of nitric oxides in combustion products were measured using mid-infrared wavelength modulation spectroscopy (WMS). NO absorption line at 1939.61 cm−1 (5.2 μm) was selected to avoid interference from water. Simulated absorption spectra with a typical combustion product mixture were generated to validate the feasibility of the selected line. The WMS scheme successfully rejected noise from turbulent fluctuations, flame emissions, etc. Peak height of the subtracted 1f normalized 2f signal was useful to quantify integrated absorbances. NO measurement was demonstrated under various conditions of flames at a flat flame burner. Noise equivalent detection limit was 8.4 ppm-m for non-reacting flow. The measurement system shows promise in assisting the development of cleaner and low-emitting advanced power generation and propulsion systems.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Park et al. (2026) studied this question.

synapsesocial.com/papers/69e320cc40886becb653fda5https://doi.org/10.1115/1.4071677
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Raman Spectroscopy for Monitoring NOx and N2O in Combustion Products2026 · 1 citations
  2. 2Spectroscopic investigation of NO transitions near 1915 cm⁻¹: high temperature line parameters and uncertainty quantification2026
  3. 3Precise Analysis of NO₂ Concentration Based on Absorption Spectroscopy in the 6.2 µm Wavelength Region Using Multi-Voigt Fitting2026
  4. 4Field deployable laser sensor for calibration-free and real-time measurement of NOx from stationary sources2024 · 3 citations
  5. 5Development of High-Precision NO2 Gas Sensor Based on Non-Dispersive Infrared Technology2024 · 17 citations