PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 13, 2026Journal of Food Composition and Analysis0 citationsOpen Access

Method optimisation for UHPLC–FLD analysis of human milk oligosaccharides

View Full Paper
KMKristīne MajoreAĶAnete ĶeķeJZJeļena Zagorska

Key Points

  • The study aims to optimize and validate a UHPLC-FLD method for quantifying human milk oligosaccharides (HMOs).
  • Developed an ultra-high-performance liquid chromatography with fluorescence detection (UHPLC-FLD) method.
  • Validated method through testing on 74 human milk samples.
  • Assessed linearity, recovery rates, limit of detection (LOD), and limit of quantification (LOQ).
  • Optimized analytical column temperature for effective separation of HMOs.
  • Achieved high linearity (r ≥ 0.98) for the quantification of HMOs.
  • Recovery rates for spiked samples ranged from 71% to 119%.
  • LOD values were between 5.698 – 7.101 µg mL -1, and LOQ values ranged between 17.267 – 21.517 μg mL −1.
  • The method demonstrated greater performance compared to existing techniques.

Abstract

Significant analytical challenges remain due to the structural diversity of HMOs, difficulties in isolation, and the lack of commercially available standards. This study develops and validates an adaptable ultra-high-performance liquid chromatography with fluorescence detection (UHPLC-FLD) for the quantification of eight specific HMOs: 2′-Fucosyllactose (2′-FL), 6′-Sialyllactose (6′-SL), 3-Fucosyllactose (3-FL), 3′-Galactosyllactose (3′-GL), 6′-Galactosyllactose (6′-GL), Lacto-N-difucohexaose I (LNDFH I), Lacto-N-difucohexaose II (LNDFH II), and Lacto-N-neotetraose (LNnT) and testing 74 human milk samples. The method for quantifying HMOs was successfully validated regarding linearity (r ≥ 0.98), recoveries rate of spiked samples ranging from 71% to 119%. For all investigated oligosaccharides, LOD ranged from 5.698 – 7.101 µg mL -1 , and LOQ values ranged between 17.267 – 21.517 μg mL −1 . This method demonstrates great performance compared to existing techniques, providing a reliable tool for the analysis of HMOs in milk. • The developed UHPLC-FLD method was successfully applied to determine 8 commonly presented oligosaccharides in human milk. • High analytical accuracy was demonstrated, with recovery rates of 71–119% for spiked milk samples. • Analytical column temperature optimisation was determinant for effective HMO separation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Majore et al. (2026) studied this question.

synapsesocial.com/papers/69b3ab0002a1e69014ccbb3dhttps://doi.org/10.1016/j.jfca.2026.109071
Ask AI
Helpful
Bookmark
Share
View Full Paper