PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 13, 2026NeuroImage0 citationsOpen Access

Advancing intraoperative brain mapping: First-in-human evaluation of flexible high-density electrocorticography grids for epilepsy surgery

View Full Paper
SHSem HoogteijlingCGCarmen GelpkeESEline Schaft

Key Points

  • This evaluation aims to assess the effectiveness of novel flexible high-density grids in improving brain mapping during epilepsy surgery.
  • Designed and tested flexible high-density electrode grids for brain mapping.
  • Evaluated the clinical utility in three epilepsy surgery cases.
  • Compared recordings between flexible grids and standard rigid grids placed on the same cortical area.
  • Flexible grids recorded similar interictal epileptiform activity compared to rigid grids.
  • Unique recordings of epileptiform activity from within resection cavities were achieved with flexible grids.
  • No adverse events were observed during the use of flexible grids.

Abstract

• We designed novel flexible high-density grids for brain mapping in epilepsy surgery. • We tested the clinical utility of the flexible grid in three epilepsy surgery cases. • The flexible grid recordings matched those of commercially available rigid grids. • The flexible grid enabled unique recordings from within resection cavities. • No device-related adverse events were observed throughout usage. Mapping epileptiform activity, specifically high frequency oscillations (HFOs), with intraoperative electrocorticography (ECoG) may guide epilepsy surgery. The most relevant recording takes place following the surgical resection to identify any residual epileptic activity. Recording HFOs is, however, challenging due to their focal and low-amplitude nature. We designed and evaluated a novel soft, flexible, and stretchable high-density electrode grid (SOFT ECoG) tailor-made for epilepsy surgery to enhance HFO detection and enable recordings from within resection cavities. In this first-in-human evaluation of flexible high-density grids, we recorded with the SOFT ECoG grids and standard rigid high-density grids in three patients. Both grids were sequentially placed on the same cortical area and recorded similar interictal epileptiform activity (spikes and HFOs). Crucially, the SOFT ECoG grid’s pliability enabled recording from relevant, but anatomically challenging, areas like the resection cavity. This was exemplified in one patient, where the SOFT ECoG identified epileptiform activity (spikes and HFOs) within a resection cavity revealing remnant epileptic tissue needing removal. This area was inaccessible to the standard rigid grid. These findings demonstrate the potential of novel flexible electrode grids to enhance intraoperative mapping of epileptiform activity including HFOs in areas inaccessible with standard rigid grids, thereby improving epilepsy surgery guidance.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hoogteijling et al. (2026) studied this question.

synapsesocial.com/papers/69b3ab2902a1e69014ccbbfehttps://doi.org/10.1016/j.neuroimage.2026.121846
Ask AI
Helpful
Bookmark
Share
View Full Paper