February 26, 2026Thermal Science and Engineering Progress0 citationsOpen Access

Numerical investigation of PCM-integrated emergency tents for energy-efficient thermal management in hot desert climates

View Full Paper
ZEZeinab EsmaeiliSVSeyed Mohammad VahidhosseiniSRSaman Rashidi

Key Points

  • This research investigates the thermal performance of PCM-integrated tents under desert conditions.
  • Numerical simulation using CFD-based transient modeling
  • Applied SST k – ω turbulence model in ANSYS Fluent
  • Incorporated solar radiation, phase change, and buoyancy effects
  • PCM integration reduced maximum indoor temperature by 14.5 K
  • Daily average temperature lowered by 9.89 K
  • Peak vertical temperature difference decreased by 31%

Abstract

• Numerical study of PCM-integrated tents for energy-efficient cooling in deserts. • CFD-based transient model addressing thermal comfort in emergency shelters. • PCM reduces indoor air stratification, lowering gradients by up to 5.4 K. • Roof PCM reaches full melting (LF ≈ 1.0) during peak solar hours. • PCM-integrated roofs store 67% more heat than wall sections. This study numerically evaluates PCMs in fabric-based emergency tents in Sistan and Baluchestan, Iran, using a passive thermal-management strategy for hot desert conditions. A two-stage CFD framework is applied: steady-state external airflow is solved with the SST k – ω turbulence model in ANSYS Fluent to obtain surface convective coefficients, while transient heat transfer inside the tent is computed via the enthalpy–porosity (mushy-zone) method, incorporating solar radiation, phase change, and buoyancy effects. Models were validated against benchmark data for PCM melting, external forced convection, and natural convection (∼7% deviation), confirming simulation reliability in capturing coupled thermal phenomena. Results show that PCM integration reduces the maximum indoor temperature from 326.75 K to 312.25 K (14.5 K/4.4% lower) and the daily average from 317.89 K to 308 K (9.89 K/3.1% lower). The peak vertical temperature difference decreases by 31%, from 17.24 K to 11.88 K. Roofs fully melted, with the West Roof storing 23.85 MJ and other PCM layers storing 16.08–19.33 MJ, while the West Wall reached ∼60% melting, yielding a total of 71.55 MJ of latent heat storage, more clearly capturing the system’s overall thermal behavior. Internal air velocities remained below 0.03 m·s −1 , indicating limited natural mixing.