March 1, 2026Scientific Reports1 citationsOpen Access

¹¹CMethionine PET uptake kinetics in corticotroph pituitary neuroendocrine tumors

AFAnthime FlausAPArmand PattéeGCGuillaume Criton

Key Points

  • To investigate the uptake kinetics of [¹¹C]methionine PET in corticotroph pituitary neuroendocrine tumors compared to normal pituitary glands.
  • Analyzed data from a multicenter cohort study of patients with confirmed corticotroph PitNETs.
  • Utilized MRI for localization of tumors before PET imaging.
  • Performed kinetic analysis of early and late tracer uptake after [¹¹C]methionine injection.
  • PitNETs exhibited significantly higher early uptake compared to the normal pituitary gland (p < 0.01).
  • Both early uptake slope and peak uptake were higher in PitNETs (p < 0.01).
  • No significant difference was found in temporal uptake pattern (p = 0.09).
  • Kinetic parameters demonstrated moderate-to-high discriminative performance with area under the curve values of 0.78 and 0.86.

Abstract

11CMethionine (11CMET) PET provides high sensitivity to localize corticotroph pituitary neuroendocrine tumors (PitNETs) in de novo Cushing’s disease but remains inconclusive in up to 20% of cases. Current PET protocols rely on late acquisitions (20–40 min post-injection). Since other endocrine tumors present earlier peak tracer uptake, corticotroph PitNETs might also exhibit early differential amino acid uptake, compared to the normal pituitary gland. This exploratory study based on data derived from a previously registered prospective multicenter cohort study (ClinicalTrials.gov identifier: NCT03346954) included 15 patients with pathologically confirmed corticotroph PitNETs accurately localized using MRI. Kinetic analysis showed rapid early uptake in PitNETs and normal pituitary gland, followed by a significant decline over time, with consistently higher uptake in PitNETs (p < 0.05), but no statistically significant difference in temporal uptake pattern (p = 0.09). Early uptake slope and peak uptake were significantly higher in PitNETs compared to normal gland (p < 0.01), with moderate-to-high discriminative performance (area under the curve 0.78; 95%CI 0.60–0.94 and 0.86; 95%CI 0.69–0.98, respectively). Time-to-peak showed no statistically significant discriminative value. These findings suggest that kinetic parameters of ¹¹CMET PET, particularly early slope and peak uptake, may provide complementary information to static PET for PitNET characterization.