PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 3, 2026Journal of Applied Polymer Science0 citationsOpen Access

Real‐Time Kinetic Monitoring of Dental Composite Photopolymerization by Photo‐ DSC

View Full Paper
RLR. LatouiDBD. BouzidMTM. Taam

Key Points

  • The degree of conversion directly affects the mechanical properties and durability of dental composites.
  • Increasing camphorquinone concentration enhanced the degree of conversion up to 70%, showing key performance thresholds.
  • Experimentation using photo-differential scanning calorimetry tracked the kinetics of photocuring processes accurately.
  • Optimizing the initiator system, particularly with diphenyliodonium hexafluorophosphate, significantly improves polymerization efficiency.

Abstract

ABSTRACT The degree of conversion (DC) of dental resin composites critically determines their mechanical properties and clinical durability. This study elucidates how formulation parameters govern the degree of conversion in Bis‐GMA/TEGDMA/silica composites using photo‐differential scanning calorimetry. This approach provides new insights into the efficiency and kinetics of photocuring in dental composite materials. Increasing the concentration of the camphorquinone/dimethylaminoethyl methacrylate (CQ/DMAEMA) photo‐initiator system from 0.2% to 1.0 wt.% enhanced the DC up to ~70%, beyond which no significant gain was observed. The incorporation of 50 wt.% silica via the sol–gel route delayed the polymerization onset but remained within clinically acceptable limits. The addition of diphenyliodonium hexafluorophosphate (DPIHP) significantly improved polymerization kinetics, reducing the DC plateau time from 40 to 10 s and increasing final conversion to ~64%. The amphiphilic nature of DPIHP enhanced radical generation by bridging hydrophilic and hydrophobic domains. At 10 wt.% water content, CQ/DMAEMA systems showed reduced reactivity due to phase separation, whereas more hydrophobic systems (CQ/4E, CQ/DPIHP) maintained higher DCs values. The presence of water slightly increased monomer mobility, contributing marginally to conversion. These findings highlight the importance of adapting the initiator system and resin formulation to optimize the polymerization performance of dental composites.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Latoui et al. (2026) studied this question.

synapsesocial.com/papers/69a75a97c6e9836116a209c8https://doi.org/10.1002/app.70452
Ask AI
Helpful
Bookmark
Share
View Full Paper