March 3, 2026Latvian Journal of Physics and Technical Sciences0 citationsOpen Access

Performance Efficiency of PEM Electrolyzer Stacks with Nano-Coated Titanium PTLS and Bipolar Plates

ABA. BackursLJL. JansonsLZL. Zemite

Key Points

  • Stacks demonstrated stable operation at high-pressure and high-current conditions, ensuring efficient gas separation.
  • At 300 A, the total voltage was 99.3 V for Stack 0316/44 and 102.8 V for Stack 0317/44, indicating slight differences in performance.
  • Average power consumption during operation was approximately 10-20% higher than standard industrial stacks, highlighting efficiency concerns.
  • Study provides a foundation for future durability assessments and optimization of coated PEM stack architectures.

Abstract

Abstract The study presents an industrial-scale evaluation of two PEM electrolyser stacks incorporating Naco-engineered titanium coatings on porous transport layers (PTLs) and bipolar plates. Stack 0316/44 included both coated PTLs and coated bipolar plates, while Stack 0317/44 utilised only coated PTLs. Both stacks were conditioned for 40 hours at 15 bar and subsequently tested at current densities of 0.6 and 1.2 A cm −2 . At 150 A, the total voltages measured were 89.8 V for 0316/44 and 88.9 V for 0317/44, whereas at 300 A, they reached 99.3 V and 102.8 V, respectively. Gas purity remained within safe limits, with residual oxygen (O 2 ) in hydrogen (H 2 ) ranging from 14 ppm to 31 ppm and H 2 crossover remaining below 0.7 % across all tests. Integrated operation in the SIRIO 1000 system at 300 A produced the combined voltages of 106.0 V and 104.0 V for the two stacks. Average power consumption during joint operation was 5.75 kW/Nm³, approximately 10–20 % higher than that of standard industrial stacks. The results confirm the stable operation and acceptable gas-separation performance of the coated components under high-pressure, high-current conditions, while also identifying efficiency gaps that require further optimisation. The study provides the first comparative industrial assessment of the coated PEM stack architectures and establishes a foundation for future durability and optimisation studies.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Backurs et al. (2026) studied this question.

synapsesocial.com/papers/69a75ac3c6e9836116a20fe2https://doi.org/10.2478/lpts-2026-0004
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Advanced Strategies for Mitigating Catalyst Poisoning in Low and High Temperature Proton Exchange Membrane Fuel Cells: Recent Progress and Perspectives2025 · 15 citations
  2. 2Advanced Electrocatalyst Supports for High-Temperature Proton Exchange Membrane Fuel Cells: A Comprehensive Review of Materials, Degradation Mechanisms, and Performance Metrics2025 · 12 citations
  3. 3Control Analysis of Renewable Energy System with Hydrogen Storage to Match Energy Community Demand: A Whole-System Perspective2025 · 2 citations
  4. 4Mechanisms and Modelling of Effects on the Degradation Processes of a Proton Exchange Membrane (PEM) Fuel Cell: A Comprehensive Review2025 · 43 citations
  5. 5Synthesis and Electrochemical Characterization of Ru-Modified Iridium Oxide Catalysts for PEM Electrolysis2024 · 5 citations