PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 8, 2026SHILAP Revista de lepidopterología1 citationsOpen Access

Paddy Stem–Derived Activated Carbon-Based Uricase Biosensor for Highly Sensitive Electrochemical Detection of Uric Acid

View Full Paper
PTPoonam ThakurNGNancy GeorgeNKNeha Kondal

Key Points

  • The primary aim is to develop a low-cost biosensor using activated carbon from paddy stems for sensitive uric acid detection.
  • Designed an electrochemical biosensor using porous activated carbon from paddy stems.
  • Characterized the carbon material using XRD, FE-SEM, HR-TEM, and XPS techniques.
  • Immobilized uricase enzyme on a carbon electrode modified with PSAC and coated it with Nafion.
  • Conducted electrochemical experiments including differential pulse voltammetry (DPV) to assess performance.
  • Achieved a low limit of detection for uric acid at 0.0715 nM.
  • Demonstrated a linear response over a concentration range of 10–1000 nM with high sensitivity of 2.2588 μA/nM.
  • Showed improved catalytic activity for uric acid oxidation compared to unmodified electrodes.
  • Successfully detected uric acid in real urine samples, exhibiting excellent selectivity and stability.

Abstract

For the diagnosis and management of metabolic diseases, such as gout, hyperuricemia, hypertension, and diabetes, accurate and timely measurement of uric acid (UA) is essential. This article presents the design of low-cost and eco-friendly enzymatic electrochemical biosensors to detect UA through the use of porous activated carbon nanomaterial (PSAC) obtained from paddy stem as the electrode modifier. Acid treatment, carbonization, and KOH activation were used to create PSAC, a high-surface-area, porous, and electrically conductive carbon nanomaterial that can be used to immobilize enzymes. XRD, FE-SEM, HR-TEM, and XPS analytical techniques were used for structural and morphological characterizations. These techniques further validated the amorphous turbostratic carbon framework with a large number of functional groups and porosity. To improve enzyme stability and reduce interference, uricase (UOx) was mounted onto the PSAC-modified glassy carbon electrode (GCE) and then coated with Nafion. When compared to unmodified electrodes, electrochemical experiments showed that the UOx/PSAC@GCE electrode demonstrated higher catalytic activity toward UA oxidation, with a notable increase in peak current and a lower oxidation potential. With a low limit of detection (LOD = 0.0715 nM) and limit of quantification (LOQ ≈ 0.215 nM), differential pulse voltammetry (DPV) displayed a linear response over the concentration range of 10–1000 nM and achieved great sensitivity (2.2588 μA/nM). The biosensor was successfully used to detect UA in actual urine samples and has given outstanding selectivity, repeatability, and stability. This study signifies the potential of carbon nanomaterials produced from agricultural waste for high-performance, sustainable biosensing platforms in clinical diagnostics.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Thakur et al. (2026) studied this question.

synapsesocial.com/papers/69ada8cfbc08abd80d5bc1echttps://doi.org/10.1155/jnt/5221579
Ask AI
Helpful
Bookmark
Share
View Full Paper