PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 18, 2026Journal of Clinical Medicine0 citationsOpen Access

Standardizing Periocular Surface Electromyography: A Scoping Review of Methods and Emerging Applications

View Full Paper
LKLarysa Krajewska-WęglewiczEFEwa FilipiakMDMałgorzata Dorobek

Key Points

  • The review aims to synthesize existing periocular sEMG methodologies and identify sources of variability to promote standardization.
  • Conducted comprehensive searches in PubMed, Embase, and Web of Science.
  • Included randomized controlled trials, observational studies, and pilot investigations.
  • Data were extracted and categorized into predefined methodological domains.
  • A thematic synthesis approach identified recurring methodological patterns.
  • Identified sixteen studies published between 2002 and 2025 that met inclusion criteria.
  • Observed considerable heterogeneity in electrode characteristics, placement strategies, and signal processing methods.
  • Developed a conceptual methodological framework and minimum reporting set to enhance reproducibility.

Abstract

Background: Surface electromyography (sEMG) of periocular muscles is a non-invasive technique used to assess eyelid dynamics and facial neuromuscular function, with applications in ophthalmology, neurology, and rehabilitation. Despite its clinical and research potential, substantial methodological variability—particularly in electrode placement, acquisition parameters, and signal processing—has limited reproducibility and hindered broader clinical translation. A comprehensive synthesis of existing methodologies was therefore needed to support future standardization. Objectives: The review aimed to systematically map current periocular sEMG methodologies, identify sources of methodological heterogeneity, organize findings into structured methodological domains, and develop a conceptual framework along with a minimum reporting set to promote transparency, reproducibility, and comparability across studies. Eligibility Criteria: Studies were eligible if they investigated surface electromyography of periocular muscles and reported methodological details related to electrode placement, signal acquisition, processing, or analysis. Randomized controlled trials, observational studies, and pilot investigations were included. No restrictions were placed on publication year. Sources of Evidence: Comprehensive searches were conducted in PubMed, Embase, and Web of Science from database inception through November 2025. Grey literature sources were also examined to enhance coverage and reduce publication bias. Charting Methods: Two reviewers independently screened records and extracted data. Extracted information was organized into predefined methodological domains. A thematic synthesis approach was used to identify recurring methodological patterns, and findings were integrated into a structured conceptual framework. Results: Sixteen studies published between 2002 and 2025 met the inclusion criteria, encompassing randomized trials, observational studies, and pilot investigations. Considerable heterogeneity was identified across studies in electrode characteristics, placement strategies, reference configurations, sampling frequencies, and normalization procedures. Three recurring methodological domains emerged: instrumentation and acquisition, analytical and normalization approaches, and clinical or experimental applications. Based on these domains, the authors developed a conceptual methodological framework and proposed a minimum reporting set intended to improve methodologyical transparency and support reproducibility and multicenter comparability. Conclusions: Periocular sEMG represents a promising yet methodologically fragmented field. This scoping review provides the first comprehensive synthesis of periocular sEMG practices and establishes an evidence-based platform for standardized acquisition, processing, and reporting. Adoption of the proposed framework may strengthen reproducibility, facilitate multicenter collaboration, and accelerate integration into clinical and research settings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Krajewska-Węglewicz et al. (2026) studied this question.

synapsesocial.com/papers/69ba429c4e9516ffd37a30a0https://doi.org/10.3390/jcm15062256
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Reproducibility of Surface EMG in the Human Masseter and Anterior Temporalis Muscle Areas2005 · 56 citations
  2. 2Alteration of Surface EMG amplitude levels of five major trunk muscles by defined electrode location displacement2014 · 32 citations
  3. 3Can Methylphenidate Objectively Provide Relief in Patients With Uncontrolled Blepharospasm? A Pilot Study Using Surface Electromyography2010 · 17 citations
  4. 4Differentiating between reflex and spontaneous blinks using simultaneous recording of the orbicularis oculi electromyogram and the electro-oculogram in startle research2002 · 24 citations
  5. 5American Association of Neuromuscular & Electrodiagnostic Medicine evidenced‐based review: Use of surface electromyography in the diagnosis and study of neuromuscular disorders2008 · 87 citations