PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 18, 20260 citationsOpen Access

Building energy efficiency assessment considering IEQ and sustainability certification data for German office buildings

RFRaik FahrichLSLukas SchumannLKLisa Kremser

Key Points

  • The aim is to evaluate building energy efficiency by considering both energy demand and indoor environmental quality ratings.
  • Assessed energy demand and indoor environmental quality ratings together.
  • Used certification data from two German office buildings for analysis.
  • Conducted a survey on IEQ factors among building users to compare results.
  • Calculated an example IEQ index based on the certification data.
  • The IEQ rating and energy demand differed significantly based on certification data and user surveys.
  • The overall performance ranged from 0.13 to 0.16 IEQ-Score per MJ m−2 a−1 for certification data compared to survey results.
  • Discrepancies reached up to 50% between different assessment methods.

Abstract

Assessing a building’s energy efficiency is a major goal to avoid unnecessary and inefficient energy-consuming renovations. Currently, building energy efficiency is measured primarily by the energy demand of the building. However, the higher energy efficiency of the building is not always aligned with the greater comfort of the occupant, which is the main benefit a building provides. In this study, indoor environmental quality (IEQ) ratings and building energy demand are considered together to evaluate building energy efficiency. It compares the IEQ comfort achieved to the energy demand of the building. An example IEQ index calculation based on certification data of two buildings assessed by a German building sustainability certification system is used. The data include scoring of different IEQ categories and information on energy usage for the buildings. In addition, a survey on IEQ factors was conducted among building users and the results were compared to those based on the certification assessment data. The IEQ rating of the building certification data based on building design and measurement data for the individual factors differed from the subject study results by up to 50%. The overall performance of the considered buildings ranged from 0.13 to 0.16 IEQ-Score per MJ m−2 a−1 for the certification data and survey results.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fahrich et al. (2025) studied this question.

synapsesocial.com/papers/69ba42ee4e9516ffd37a3960https://doi.org/10.14279/depositonce-24853
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Building energy characteristic evaluation in terms of energy efficiency and ecology2024 · 12 citations
  2. 2Bridging Green Certification and Occupant Well-Being: A Mixed Methods Study of IEQ and Quality of Life in Certified and Non-Certified Malaysian Office Buildings2026
  3. 3Examining Energy Efficiency Practices in Office Buildings through the Lens of LEED, BREEAM, and DGNB Certifications2024 · 8 citations
  4. 4Analysis of Improvement in the Energy Efficiency of Office Buildings Based on Energy Performance Certificates2024 · 3 citations
  5. 5Experimental and Simulation Analysis of IEQ and Energy Demand in an Office Building in Northern Greece2025