PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 18, 2026BMC Medical Imaging0 citationsOpen Access

Uncertainty-aware automated labeling of intracranial arteries using deep learning

View Full Paper
JBJavier BisbalPWPatrick WinterSJSebastián Jofre

Key Points

  • The study aims to enhance automated labeling of intracranial arteries by incorporating uncertainty quantification into deep learning frameworks.
  • Developed an uncertainty-aware deep learning framework for artery labeling from 3D ToF-MRA segmentations.
  • Evaluated three convolutional neural network architectures: UNet, CS-Net, and nnUNet.
  • Used test-time augmentation and a coordinate-guided strategy to model confidence during inference.
  • Assessed generalizability using the public TubeTK ToF-MRA dataset.
  • nnUNet achieved the highest performance with an average Dice score of 0.93 and average surface distance of 0.35 mm.
  • On the TubeTK dataset, nnUNet maintained a Dice score of 0.87 and average surface distance of 0.42 mm.
  • Validation against co-registered 4D flow MRI showed close agreement with no significant differences.

Abstract

Accurate anatomical labeling of intracranial arteries is critical for cerebrovascular diagnosis and hemodynamic analysis, but remains time-consuming and prone to inter-operator variability. While deep learning provides an automated solution, its clinical adoption is limited by the lack of confidence measures. Incorporating uncertainty quantification into automated labeling could enhance interpretability by identifying ambiguous or abnormal regions and support clinical trust, yet this aspect remains underexplored. To address this gap, we introduce an uncertainty-aware deep learning framework for automated artery labeling from 3D Time-of-Flight Magnetic Resonance Angiography (3D ToF-MRA) segmentations (n = 35). Three convolutional neural network architectures were evaluated: (1) UNet with residual encoder blocks, (2) CS-Net, an attention-augmented UNet with spatial attention, and (3) nnUNet, a self-configuring framework that adapts architecture and training to dataset characteristics. Confidence was modeled via test-time augmentation (TTA) combined with a novel coordinate-guided strategy to reduce interpolation errors during inference. Generalizability was assessed by evaluating a subset of the public TubeTK ToF-MRA dataset (n = 20). Voxelwise uncertainty maps highlighted anatomical ambiguities, pathological variations, and inconsistencies in manual references, providing intuitive confidence indicators. nnUNet achieved the highest performance (average Dice score 0.93; clDice 0.94; average surface distance 0.35 mm; 95th percentile of Hausdorff distance 4.51 mm), demonstrating robustness in complex vascular regions. On the TubeTK dataset, nnUNet maintained robust generalization (average Dice score 0.87; clDice 0.87; average surface distance 0.42 mm; 95th percentile of Hausdorff distance 5.85 mm). Validation against co-registered 4D flow MRI showed close agreement between flow velocities derived from automated and manual labels, with no significant differences. The proposed framework delivers a scalable, accurate, and uncertainty-aware solution for intracranial artery labeling. By integrating uncertainty quantification, it offers a transparent and clinically trustworthy tool to facilitate cerebrovascular imaging workflows and support subsequent hemodynamic analyses.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bisbal et al. (2026) studied this question.

synapsesocial.com/papers/69ba434a4e9516ffd37a469ehttps://doi.org/10.1186/s12880-026-02276-5
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Unified segmentation2005 · 7,612 citations
  2. 2Problems and pitfalls of 3-D TOF Magnetic resonance angiography of the intracranial circulation1995 · 63 citations
  3. 3Complete Intracranial Arterial and Venous Blood Flow Evaluation with 4D Flow MR Imaging2008 · 60 citations
  4. 4Anatomical Studies of the Circle of Willis in Normal Brain1959 · 501 citations
  5. 5A manifesto on explainability for artificial intelligence in medicine2022 · 162 citations