March 22, 2026World Allergy Organization Journal0 citationsOpen Access

Characterization and diagnostic evaluation of hypersensitivity to iodinated contrast media: A retrospective analysis

View Full Paper
GBGabija BrusokienėKLKotryna LinauskienėKČKęstutis Černiauskas

Key Points

  • To differentiate between immune-mediated hypersensitivity and non-immune adverse reactions to iodinated contrast media (ICM).
  • Conducted retrospective analysis of 222 patients at Vilnius University Hospital Santaros Clinics from 2017 to 2024.
  • Performed skin prick and intradermal testing on all patients.
  • Selected patients underwent intravenous provocation testing.
  • Confirmed sensitization to ICM in 16.67% of patients, primarily through intradermal and provocation testing.
  • Significant association of urticaria (OR = 3.93) and anaphylaxis (OR = 4.17) with confirmed sensitization.
  • Higher sensitization rates observed in oncologic (29.63%) and cardiovascular (20.69%) conditions, while renal pathology showed the lowest rate (2.94%).

Abstract

Background: Hypersensitivity reactions to iodinated contrast media (ICM) pose a growing clinical challenge, especially for patients requiring imaging.Differentiation of immune-mediated hypersensitivity from non-immune adverse reactions is essential to avoid unnecessary ICM avoidance and ensure safe diagnostic imaging procedures. Methods:We conducted a retrospective analysis of 222 patients assessed for suspected ICM hypersensitivity at Vilnius University Hospital Santaros Clinics from 2017 to 2024.All patients underwent skin prick and intradermal testing.Selected individuals received intravenous provocation testing.Clinical characteristics, symptom profiles, and outcomes were assessed.Results: Sensitization to ICM was confirmed in 16.67% of patients, primarily via intradermal and provocation testing.Urticaria (OR = 3.93) and anaphylaxis (OR = 4.17) were significantly associated with confirmed sensitization, while isolated non-cutaneous symptoms and late-onset angioedema were not.Higher sensitization rates were observed in patients with oncologic (29.63%) and cardiovascular (20.69%) conditions, and renal pathology showed the lowest rate (2.94%).Among non-sensitized patients, 75 underwent ICM imaging without adverse reactions and were safely delabeled.Most sensitized individuals tolerated alternative ICM agents. Conclusions:A tiered allergological approach using skin and provocation testing supports accurate diagnosis and risk-stratified imaging strategies, including safer alternative ICM selection and selective delabeling.Findings support early referral, personalized contrast selection, and delabeling strategies in high-risk populations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Brusokienė et al. (2026) studied this question.

synapsesocial.com/papers/69bf8692f665edcd009e8df5https://doi.org/10.1016/j.waojou.2026.101366
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1555 Frequency, Characteristics and Outcome of Immediate Hypersensitivity Reactions Due to Iodinated Contrast Media2012 · 1 citations
  2. 2What can we learn in drug allergy management from World Health Organization's international classifications?2017 · 40 citations
  3. 3EAACI position paper on how to classify cutaneous manifestations of drug hypersensitivity2018 · 243 citations
  4. 4Prevention of Allergic-like Reactions at Repeat CT: Steroid Pretreatment versus Contrast Material Substitution2021 · 53 citations
  5. 5Hypersensitivity reactions to iodinate contrast media in Italy: a retrospective study. Characteristics of patients and risk factors2021 · 26 citations