March 25, 2026Agronomy1 citationsOpen Access

Dynamics of Droplet Spectra and Physicochemical Properties Under Different Adjuvants and Spraying Pressures

View Full Paper
SBSérgio BasílioMJM. Carneiro JúniorCACleyton Batista de Alvarenga

Key Points

  • The aim is to evaluate the impact of various adjuvants and spraying pressures on droplet size distribution and physicochemical properties.
  • Measured pH, volumetric mass, electrical conductivity, surface tension, and contact angle of solutions.
  • Employed a laser diffraction particle analyzer to determine droplet spectrum variables.
  • Conducted spraying tests with varying pressures using AXI 11003 flat fan nozzle.
  • Higher spraying pressures increased the volume of fine droplets (V100) and the Relative Span Factor (RSF).
  • Adjuvants AS, MO2, and OS resulted in a balanced droplet size distribution with fewer fine droplets.
  • Principal component analysis indicated the droplet spectrum variables were key to explaining variation among solutions.

Abstract

Droplet size is a key factor in minimizing spray drift. Different types of adjuvants and sprayer operating pressures can affect the droplet size distribution in various ways. This study aimed to evaluate the effects of commercial adjuvants, namely, acids and surfactant (AS), silicone surfactant (SS), organosilicone surfactant (OS), mineral oil (MO and MO2), and copolymer (CP) adjuvants, on the droplet spectra and physicochemical properties of aqueous solutions. Hydrogen potential (pH), volumetric mass (VM), electrical conductivity (EC), surface tension (ST), contact angle (CA), and droplet spectra were measured. The droplet spectrum variables, including volumetric diameters (Dv0.1, Dv0.5, and Dv0.9), the Relative Span Factor (RSF), and percentages of the total volume of droplets with a diameter smaller than 100 µm (V100) and larger than 500 µm (V500), were determined using a laser diffraction particle analyzer (Malvern Spraytec). Spraying tests were carried out using the AXI 11003 flat fan nozzle at pressures of (0.1, 0.2, 0.3, 0.4, and 0.5) MPa. The increase in pressure increased the V100 and the RSF, with greater sensitivity observed for SS. Adjuvants such as AS, MO2 and OS showed a more balanced trend, with a smaller increase in fine droplets and a greater reduction in coarse droplets. The principal component analysis (PCA) revealed that the droplet spectrum variables were the ones that best explained the variation among the solutions. A negative correlation was identified between EC and other physicochemical properties, such as pH, ST, and CA. Therefore, these properties alone did not determine the atomization pattern. The study demonstrates that optimizing spray quality and minimizing drift require a combined consideration of adjuvant physicochemical properties and their interaction with operational pressure.