April 1, 2026Cureus0 citationsOpen Access

Initial Experience With Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis in Nicaragua

ILIvonne Dessireé LeytónJCJairo CamposEGErick Gutierrez

Key Result

Transcatheter aortic valve replacement achieved a 93.8% early safety rate and reduced the median transaortic pressure gradient from 52.5 mmHg to 9.0 mmHg at 30 days.

Key Points

  • The study aimed to evaluate the initial national experience with TAVR in patients with severe aortic stenosis in Nicaragua.
  • Retrospective descriptive case series
  • Included 16 patients who underwent TAVR
  • Used VARC-3 criteria for evaluating outcomes
  • Baseline clinical and echocardiographic data were analyzed
  • Statistical analysis performed with IBM SPSS Statistics 25
  • Majority aged 61-70 years with mean age of 68.9 years
  • 13 out of 16 procedures met VARC-3 criteria for technical success
  • Device success achieved in 12 patients (75%)
  • Post-procedural mean gradient decreased significantly to 9.08 mmHg
  • No intraprocedural or 30-day deaths reported

Study Design

Type

Observational (n=16)

Multicenter

No

Structured PICO

P
Population
Patients with confirmed severe aortic stenosis and high surgical risk, mean age 68.9 years, 56.3% male
I
Intervention
Transcatheter aortic valve replacement (TAVR)
O
Outcome
Valve Academic Research Consortium-3 (VARC-3) criteria, including technical success, device success, and early safety at 30 dayscomposite

TAVR is feasible and achieves favorable short-term safety and hemodynamic outcomes in high-risk patients with severe aortic stenosis in Nicaragua.

Main Result

Absolute Event Rate: 9% vs 52.5%

p-value: p=<0.001

Limitations

  • Single-center descriptive case series with a small sample size
  • Clinical documentation and procedural reporting were not fully standardized during the early implementation phase
  • Short follow-up period of 30 days

Abstract

Background Aortic stenosis is a progressive valvular disease strongly associated with aging and high mortality once symptoms develop. Surgical aortic valve replacement has traditionally been the standard treatment for symptomatic severe disease; however, transcatheter aortic valve replacement (TAVR) has emerged as an effective, less invasive alternative for patients with increased surgical risk, supported by evidence from major clinical trials. Since its introduction in Nicaragua, procedural volume has steadily increased. This study aimed to describe the initial national experience with TAVR in patients with severe aortic stenosis in Nicaragua. Materials and methods This retrospective descriptive case series included 16 patients with confirmed severe aortic stenosis who underwent TAVR between July 2023 and March 2024 at a single center in Managua, Nicaragua. Baseline clinical and echocardiographic data were obtained from medical records. Outcomes were evaluated using Valve Academic Research Consortium-3 (VARC-3) criteria, including technical success, device success, and early safety at 30 days. Data were analyzed using IBM SPSS Statistics 25 (IBM Corp., Armonk, NY) with categorical variables reported as n (%), continuous variables as mean ± SD, and pre- versus post-procedural mean transaortic pressure gradients compared using the Wilcoxon signed-rank test. Statistical significance was defined as p ≤ 0.05, which was calculated through Fisher's exact test (dichotomous variables) and Fisher-Freeman-Halton exact test (polytomous variables). Institutional review board approval was obtained. Results The majority of participants were in the 61-70 year age group, accounting for 7 (43.8%) patients, with a mean age of 68.9 ± 8.7 years; 9 (56.3%) were male, and 9 (56.3%) were overweight. The most prevalent comorbidities were hypertension in 15 (93.8%) and diabetes mellitus in 6 (37.5%). Dyspnea was the most common symptom, reported in 15 (93.8%), followed by heart failure in 9 (56.3%) and angina in 8 (50%). Baseline hemodynamics showed a mean transaortic gradient of 55.7 ± 21.1 mmHg, with 14 (87.5%) presenting gradients >40 mmHg, and a mean aortic valve area of 0.68 ± 0.3 cm². Self-expanding valves were implanted in 15 (93.8%), predominantly Acurate Neo 2 in 13 (81.3%) (Boston Scientific Corp., Marlborough, MA). Overall, 13 (81.3%) procedures met VARC-3 criteria for technical success. No intraprocedural or 30-day deaths were recorded. At 30 days, device success was achieved in 12 (75%), early safety in 15 (93.8%), and intended valve performance was satisfactory in 14 (87.5%), with a post-procedural mean gradient of 9.08 ± 6.3 mmHg and no moderate-to-severe aortic regurgitation. The median transaortic pressure gradient decreased from baseline to 30 days after TAVR, from 52.5 (IQR 41.5-67.5) to 9.0 (IQR 3.47-11), with p<0.001 indicating a statistically significant change and a substantial clinical impact on patients’ hemodynamic status. Permanent pacemaker implantation and paravalvular leak occurred in 1 (6.3%) patient each. Conclusion In this initial single-center experience in Nicaragua, TAVR was feasible and achieved favorable short-term outcomes, with significant improvement in transaortic hemodynamics at 30 days. These findings support the early safety and effectiveness of TAVR in this setting, although larger prospective studies are needed to confirm results and improve generalizability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Leytón et al. (2026) conducted an observational in Severe aortic stenosis (n=16). Transcatheter aortic valve replacement (TAVR) vs. Baseline was evaluated on Median transaortic pressure gradient (mmHg) at 30 days (p=<0.001). Transcatheter aortic valve replacement achieved a 93.8% early safety rate and reduced the median transaortic pressure gradient from 52.5 mmHg to 9.0 mmHg at 30 days.

synapsesocial.com/papers/69cd79915652765b073a67ebhttps://doi.org/10.7759/cureus.106149
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery2010 · 7,227 citations
  2. 2Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years2023 · 620 citations
  3. 3Aortic valve function post-replacement of severe aortic stenosis by transcatheter procedure versus surgery: a systematic review and metanalysis2021 · 4 citations
  4. 4Five-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement2020 · 838 citations
  5. 5Clinical Comparison of a Novel Balloon-Expandable Versus a Self-Expanding Transcatheter Heart Valve for the Treatment of Patients with Severe Aortic Valve Stenosis: The EVAL Registry2022 · 39 citations