PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 12, 2026Catheterization and Cardiovascular Interventions0 citations

Transcatheter Aortic Valve Replacement in a Perceval Valve: Pitfalls, Tips, and Outcomes

View Full Paper
RERyaan EL‐AndariAHAli Fatehi HassanabadSWShaohua Wang

Key Result

Valve-in-valve TAVR in Perceval surgical valves requires specific procedural techniques to avoid wire misplacement and coronary obstruction, yielding high success rates and low mortality in prior data.

Key Points

  • The aim is to evaluate the challenges and outcomes of using the Perceval valve in transcatheter aortic valve replacement procedures.
  • Discussed strategies to prevent guidewire and catheter misplacement.
  • Outlined positioning techniques for TAVR valves relative to the Perceval valve.
  • Emphasized preoperative imaging and intraoperative techniques to prevent coronary obstruction.
  • High rates of successful valve-in-valve TAVR procedures noted.
  • Low incidences of major bleeding, coronary obstruction, and mortality reported.
  • Favorable outcomes reinforced by previous literature on the subject.

Structured PICO

P
Population
Patients with a prior Perceval sutureless surgical aortic valve undergoing valve-in-valve transcatheter aortic valve replacement (ViV TAVR)
I
Intervention
Valve-in-valve transcatheter aortic valve replacement (ViV TAVR)

ViV TAVR in Perceval valves is feasible and associated with favorable outcomes, provided specific technical strategies are employed to mitigate risks such as coronary obstruction and wire misplacement.

Abstract

The Perceval valve (Corcym, Milan, Italy) is the only sutureless surgical aortic valve replacement (SAVR) on the market. With widespread use of the Perceval valve, valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) have been increasingly reported. While the Perceval provides a favorable initial valve choice for ViV TAVR, specific challenges exist. The Perceval stent design poses a risk of the guidewire and catheter becoming misplaced between the valve stent and the aortic wall which can be mitigated by confirming wire location on multiple imaging views, using a stiff pigtail catheter, and advancing a wire through a septal puncture and antegrade through the valve and snare the wire to guide it into the ventricle. TAVR valve positioning should aim to align the inflow of the TAVR valve with the inflow of the Perceval valve for self-expanding valves. For balloon expandable valves, the outflow of the TAVR should be aligned proximally to the distal stent taper of the Perceval. Finally, coronary obstruction risk should be considered on preoperative imaging with intraoperative wire access, prophylactic snorkel stent placement, or leaflet modification techniques to mitigate the risk of coronary obstruction in high-risk patients. Previously published literature has demonstrated high rates of successful ViV TAVR in Perceval. The outcomes have also been favorable with low rates of major bleeding, coronary obstruction, annular rupture, and mortality. Future studies should aim to better characterize aortic root anatomy following SAVR to determine the suitability of specific surgical valves for future ViV TAVR.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

EL‐Andari et al. (2026) conducted a review in Aortic valve disease requiring valve-in-valve TAVR. Valve-in-valve transcatheter aortic valve replacement (ViV TAVR) in Perceval valve was evaluated. Valve-in-valve TAVR in Perceval surgical valves requires specific procedural techniques to avoid wire misplacement and coronary obstruction, yielding high success rates and low mortality in prior data.

synapsesocial.com/papers/69db38534fe01fead37c68d7https://doi.org/10.1002/ccd.70619
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Valve-in-Valve TAVR for Degenerated Perceval Valves2026
  2. 2Outcomes of Valve-in-Valve (VIV) Transcatheter Aortic Valve Replacement (TAVR) after Surgical Aortic Valve Replacement with Sutureless Surgical Aortic Valve Prostheses Perceval™: A Systematic Review of Published Cases2024 · 5 citations
  3. 3Transcatheter Versus Sutureless Aortic Valve Replacement: A Propensity-Matched Single-Center Cohort Study2026
  4. 4Self-expandable valve-in-valve transcatheter aortic valve implantation for a failed sutureless Perceval bioprosthesis: a case report2026
  5. 5A series of four transcatheter aortic valve replacement in failed Perceval valves2020 · 11 citations