April 17, 20260 citationsOpen Access

Reporting of D-dimer Testing in Venous Thromboembolism Diagnostic Management Studies: A Scoping Review.

View Full Paper
RHRobin HofstetterCMCaterina E. MarxNKNoémie Kraaijpoel

Key Points

  • To evaluate how D-dimer testing is reported in venous thromboembolism diagnostic management studies.
  • Systematic search of MEDLINE and Embase from 1999 to 2024
  • Inclusion of studies evaluating VTE diagnostic management with D-dimer testing
  • Analysis of reporting characteristics such as assay name, manufacturer, and performance parameters.
  • 58 studies included from 9,670 screened articles
  • 90% of studies reported assay name and 85% reported manufacturer
  • Only 5.2% reported detection limits; many analytical parameters were unmentioned
  • D-dimer assays varied widely in thresholds and unit types.

Abstract

Background D-dimer testing is widely integrated into diagnostic algorithms for venous thromboembolism (VTE). However, the lack of standardization across D-dimer assays and reporting may limit comparability of study findings. Objective To summarize reporting of essential characteristics of D-dimer testing in VTE diagnostic management studies. Methods We systematically searched MEDLINE and Embase from 01/1999-08/2024 for VTE diagnostic management studies that evaluated diagnostic algorithms including D-dimer testing and followed patients for ≥4 weeks after VTE was excluded. The primary outcome was reporting of D-dimer assay characteristics. Secondary outcomes were reporting of patient numbers and failure rates per assay. Results Of 9,670 articles screened, 58 studies were included: 36 (62%) enrolled patients with suspected pulmonary embolism, 21 (36%) with suspected deep vein thrombosis, and one with suspected VTE. Sample sizes ranged from 191-5,400; follow-up was 1-6 months. Assay name was fully reported in 52/58 (90%), manufacturer in 49/58 (85%), unit magnitude in 42/46 (91%), and unit type in 8/46 (17%) studies. Detection limit was reported in 3/58 (5.2%) studies; other analytical performance parameters were unreported. Nineteen quantitative assays were used across 19 combinations of thresholds and unit magnitudes. Of 17 studies using multiple assays, 9 reported patient numbers per assay and one reported failure rates per assay. Conclusion Key characteristics of D-dimer testing were inconsistently reported in VTE diagnostic management studies. While assay name, manufacturer, unit magnitude, and thresholds were often included, unit type and assay-specific data were frequently omitted. Minimum reporting standards for D-dimer testing are needed for VTE diagnostic management studies.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hofstetter et al. (2026) studied this question.

synapsesocial.com/papers/69e1ceaa5cdc762e9d857b4ehttps://doi.org/10.48620/96982
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Clinical evaluation of eight different D-dimer tests for the exclusion of deep venous thrombosis in primary care patients2015 · 33 citations
  2. 2The Clinical Utility of D-dimer Testing in Diagnosing Venous Thromboembolic Disease2003
  3. 3Effectiveness of D-dimer as a screening test for venous thromboembolism: An update2014 · 180 citations
  4. 4Variable Performance of D-dimer Testing by Hemostasis Laboratories: The Australasian/Asia-Pacific Experience2024 · 7 citations
  5. 5The Role of D‐Dimer in the Diagnosis of Deep Venous Thrombosis and Pulmonary Embolism2007 · 1 citations