April 21, 2026Düzce Üniversitesi Bilim ve Teknoloji Dergisi0 citationsOpen Access

Thermo-Hydraulic Performance Optimization of Intrusion-Type Curved Fins in Tube-Bank Heat Exchangers Using Response Surface Methodology

OYOrhan Yalçınkaya

Key Points

  • The aim is to optimize the thermo-hydraulic performance of tube-bank heat exchangers using a novel fin design.
  • Conducted a numerical investigation using a 3D CFD framework in ANSYS Fluent with the RNG k–ε model.
  • Examined impacts of four geometric parameters and Reynolds number using Response Surface Methodology.
  • Utilized Central Composite Design to develop surrogate models for optimal fin configuration.
  • Identified optimal fin design parameters resulting in a maximum thermo-hydraulic performance factor of 1.53.
  • Enhanced heat transfer observed with optimized configuration compared to baseline design.
  • Intensified longitudinal vortex structures improved heat transfer efficiency.

Abstract

Flow separation and wake formation around circular tubes are among the primary causes of pressure losses and limited heat transfer performance in tube-bank heat exchangers (TBHEs). In this study, the thermo-hydraulic performance of a staggered circular tube-bank heat exchanger enhanced with a novel Inward Curved Ring-Winglet (ICRW) configuration was numerically investigated. Unlike conventional external fins that primarily increase surface area, the proposed intrusion-type design modified the core flow by partially penetrating into the channel region, promoting longitudinal vortex formation while suppressing wake recirculation. A three-dimensional steady-state CFD framework was developed in ANSYS Fluent using the RNG k–ε turbulence model to analyze airflow and heat transfer characteristics. The effects of four geometric parameters, namely winglet length (L), winglet gap (G), inclination angle (θ), and channel height (H), together with the Reynolds number (Re), were systematically examined using Response Surface Methodology (RSM). A Central Composite Design–based RSM framework was employed to construct surrogate models and identify the optimal design by maximizing the thermo-hydraulic performance factor (TPF). The performance evaluation was based on the TPF, which accounts for both Colburn j-factor and friction factor. The investigated parameter ranges were L = 12.5–22.5 mm, G = 0.75–2.25 mm, θ = 3.75°–15°, H = 3.125–12.5 mm, and Re = 1100–11500. The RSM analysis identified an optimal configuration at L = 22.105 mm, G = 2.10 mm, θ = 5.12°, and H = 3.14 mm, for which the maximum TPF of 1.53 was achieved at Re = 11239. Compared to the baseline tube-bank configuration, the optimized ICRW design significantly enhances heat transfer while maintaining acceptable pressure losses. Flow visualization results indicate that the improvement is mainly attributed to intensified longitudinal vortex structures and effective disruption of thermal boundary layers. The results demonstrate that intrusion-type ICRW fins provide a compact and effective passive enhancement strategy for high-performance air-side TBHE applications.