Detection of cytokine release syndrome using wearables and cytokine profiling following CAR-T therapy for myeloma

SRSridevi RajeeveMWMatt WilkesNZNicole Zahradka

Key Points

  • The study aims to evaluate the feasibility of using wearable devices to monitor and detect cytokine release syndrome in patients undergoing CAR-T therapy for multiple myeloma.
  • Conducted a prospective, single-center observational pilot study with 30 patients receiving CAR-T therapy.
  • Used wearable devices to collect vital signs such as temperature, oxygen saturation, respiratory rate, and heart rate.
  • Analyzed peripheral blood cytokines using a multiplex proteomic platform before and after infusion.
  • Cytokine release syndrome occurred in 20 out of 25 evaluable patients.
  • The best wearable model detected 18 of 20 CRS episodes, with a sensitivity of 0.72 and specificity of 0.80.
  • Median adherence during high-risk periods was 71%, with a median lead time of 7 hours before nursing recognition.

Abstract

BACKGROUND: Chimeric antigen receptor T-cell (CAR-T) therapies have revolutionized treatment for relapsed/refractory multiple myeloma (RRMM). However, cytokine release syndrome (CRS), a common and potentially severe complication, requires inpatient monitoring, limiting access and increasing costs. Wearable devices could support outpatient CAR-T delivery, but feasibility for CRS detection versus standard care remains unproven. METHOD: We conducted a prospective, single-center observational pilot study to assess the feasibility of using wearable devices for monitoring vital signs and detecting CRS. Thirty patients receiving idecabtagene vicleucel (ide-cel) or ciltacabtagene autoleucel (cilta-cel) were enrolled; 25 with sufficient monitoring data were evaluable. Sensors collected skin and axillary temperature, oxygen saturation, respiratory and heart rate, and motion. Peripheral blood cytokines were analyzed pre- and post-infusion using a multiplex proteomic platform. The primary outcome was feasibility, assessed by CRS detection sensitivity and specificity; secondary outcomes included adherence, lead time, and performance of models integrating wearable and cytokine data. RESULTS: CRS occurred in 20 of 25 patients. The best-performing wearable model detected 18 or 20 CRS episodes with a sensitivity of 0.72 (mean 0.75; 95% CI 0.60-0.91) and a specificity of 0.80 (mean 0.76; 95% CI 0.68-0.84), and a median lead time of 7:00 hours before nursing recognition. Median adherence during high-risk periods was 71%. Cytokine changes paralleled temperature elevations, and IFN-γ emerged as a consistent biomarker. CONCLUSION: Wearable devices are feasible for early CRS detection and may support outpatient CAR-T care. Larger outpatient studies are warranted. TRIAL REGISTRATION: This study did not meet the criteria for ClinicalTrials.gov registration.