PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 8, 2026Scientific Reports0 citationsOpen Access

Longitudinal assessment of thrombin generation using calibrated automated thrombography in patients with continuous-flow left ventricular assist devices over a five-year period

AKAgnieszka KuczajMSMichał SkrzypekBHBartosz Hudzik

Key Points

  • Characterize changes in coagulation parameters over five years in patients with LVAD support.
  • Prospective longitudinal study of 85 patients with LVAD support, analyzed over five years
  • Basic coagulation parameters assessed at multiple time points, including baseline and every 6 months thereafter
  • Only patients completing all follow-up visits (N=22) were included for analysis
  • Significant shift toward a hypocoagulable state with increased lagtime and decreased thrombin potential (P < 0.001)
  • Increased albumin and hemoglobin levels, decreased bilirubin, creatinine, and NT-proBNP (P < 0.05)
  • No significant correlation between coagulation parameters and adverse clinical events in the group

Abstract

Despite improved survival, patients with advanced heart failure receiving long-term left ventricular assist device (LVAD) support remain at risk of serious complications, including pump thrombosis, ischemic stroke, and bleeding. LVAD therapy may contribute to persistent alterations in the hemostatic system, the impact of which on adverse clinical events remains unclear. The aim of the study was to characterize longitudinal alterations in coagulation in patients supported with continuous-flow LVADs, assessed using the Calibrated Automated Thrombogram (CAT) assay. Basic coagulation parameters were assessed at baseline, 3–4 months, 6–12 months, and every 6 months thereafter. Only patients completing all four scheduled follow-up visits were included in further analyses. Eighty-five patients were recruited; 22 met the inclusion criteria. Significant shift toward a hypocoagulable state was observed: increase in thrombin generation lagtime, decrease in endogenous thrombin potential and peak thrombin concentration (P < 0.001). Markers of persistent fibrinolytic activity were observed. LVAD support was associated with increased albumin and hemoglobin levels, decreased bilirubin, creatinine, and NT-proBNP concentrations (P < 0.05). No significant differences were observed between CAT parameters and adverse events in the investigated group. Long-term LVAD therapy was associated with progressive changes in coagulation parameters, despite a stable anticoagulant and antiplatelet treatment regimen.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kuczaj et al. (2026) studied this question.

synapsesocial.com/papers/69fd7e00bfa21ec5bbf062fbhttps://doi.org/10.1038/s41598-026-51694-6
Ask AI
Helpful
Bookmark
Share
View Full Paper