PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 8, 2026European Stroke Journal0 citationsOpen Access

Abstract Number: Esoc2026a1972 Spontaneous Changes in Resting-State Bold Mri With End-Tidal Co2 as a Non-Invasive Alternative to Gas Challenge for Assessing Cerebrovascular Reactivity

View Full Paper
VHVanessa HydeAWAlastair WebbJTJ M Price Thomas

Key Points

  • This study aims to evaluate if resting-state BOLD MRI can serve as a non-invasive alternative to CO₂ inhalation for assessing cerebrovascular reactivity in patients with cerebral small vessel disease.
  • Crossover design OxHARP trial with sildenafil versus placebo for three weeks.
  • Resting-state high-frequency BOLD MRI conducted alongside end-tidal CO₂ measurement.
  • Cerebrovascular reactivity determined through correlation of BOLD signal changes with end-tidal CO₂ changes.
  • Significant agreement in GM CVR (r=0.629, p<0.001) and WM CVR (r=0.598, p<0.001) between challenge-CVR and resting-state CVR.
  • Sildenafil increased CVR in both acquisitions, but only challenge-CVR results showed significant changes in GM and WM (GM p=0.0108, WM p=0.0020).
  • Resting-state CVR may be viable for large-scale assessments, especially in less tolerant individuals.

Abstract

Abstract Background and aims Cerebrovascular reactivity (CVR) is impaired in cerebral small vessel disease (CSVD), commonly assessed using CO₂ inhalation during MRI. However, this is methodologically challenging and uncomfortable. We assessed whether resting-state BOLD may provide a non-invasive alternative. Methods The crossover-design OxHARP trial tested three weeks of sildenafil versus placebo on MRI-CVR, assessed by 6%-CO₂ gas challenge. Resting-state, high-frequency BOLD-MRI (TR=0.4s, multiband 6) was also acquired with concurrent measurement of end-tidal CO2. After motion correction, high-pass filtering, brain extraction and voxel-wise correction for temporal delays, CVR was determined as correlation between standardised BOLD per mmHg change in etCO2, within grey (GM) and white matter (WM). Agreement between scans was determined by ICC and linear regression, and effects of drug treatment by mixed-effects linear models. Results Across 93 scans, there was significant agreement between challenge-CVR and resting-state CVR in GM (r=0.629, p0.001, ICC=0.773) and WM (r=0.598, p0.001, ICC=0.749). There was a similar voxel-wise pattern of increased CVR on sildenafil with both acquisitions, but the average difference by ROIs was only significant with challenge-CVR (Challenge: GM p=0.0108, WM p=0.0020; Resting-state: GM p=0.20, WM: p=0.099). Conclusions Optimised resting-state scanning demonstrates strong agreement with CO₂ gas challenge measures of CVR and may provide a feasible alternative for large-scale CVR assessment, or in populations where individuals are less able to tolerate a gas challenge. However, gas challenges remain optimal for cleanly detecting drug-induced CVR changes in clinical trials. Conflict of interest Vanessa Hyde: nothing to disclose Figure 1 - belongs to Results Figure 2 - belongs to Results

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hyde et al. (2026) studied this question.

synapsesocial.com/papers/69fd7f4fbfa21ec5bbf07d53https://doi.org/10.1093/esj/aakag023.924
Ask AI
Helpful
Bookmark
Share
View Full Paper