PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 1979Analytical Chemistry379 citations

Calibration of methanol and ethylene glycol nuclear magnetic resonance thermometers

View Full Paper
DRDavid S. RaifordCFCherie L. FiskEBEdwin D. Becker

Key Points

Key points are not available for this paper at this time.

Abstract

ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTCalibration of methanol and ethylene glycol nuclear magnetic resonance thermometersDavid S. Raiford, Cherie L. Fisk, and Edwin D. BeckerCite this: Anal. Chem. 1979, 51, 12, 2050–2051Publication Date (Print):October 1, 1979Publication History Published online1 May 2002Published inissue 1 October 1979https://pubs.acs.org/doi/10.1021/ac50048a040https://doi.org/10.1021/ac50048a040research-articleACS PublicationsRequest reuse permissionsArticle Views1739Altmetric-Citations323LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose Get e-Alerts

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Raiford et al. (1979) studied this question.

synapsesocial.com/papers/6a01eafabd6301933f5ccfcbhttps://doi.org/10.1021/ac50048a040
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Evaluation of the nuclear magnetic resonance total line shape analysis of uncoupled, exchanging two-site systems1972 · 48 citations
  2. 2Calibration of the methanol and glycol nuclear magnetic resonance thermometers with a static thermistor probe1968 · 529 citations
  3. 3The Analysis of C6 to C10 Aromatic Hydrocarbons in The Presence of C1 to C11 Saturated Hydrocarbons By Open Tubular Column Gas Chromatography1969 · 33 citations
  4. 4Hydrocarbon Group Types in Gasoline-Range Materials by High Performance Liquid Chromatography1975 · 87 citations
  5. 5Temperature Measurement in Nuclear Magnetic Resonance with a Spinning Thermistor1969 · 6 citations