September 10, 2025African Journal of Biomedical Research0 citations

Stress Distribution Analysis Of Extra-Short Implants With Straight Abutments Under Axial Loading: A Finite Element Study

View Full Paper
SNShreyas K NazirkarPPPrashant PatilDJDr.Premraj Jadhav

Key Points

  • The larger-diameter 5×5 mm implant displayed lower stress values compared to the smaller 5×4 mm implant.
  • Highest stress concentration was observed in cortical bone, with significant values in implant and abutment.
  • 3D models of the implants were analyzed using finite element analysis under a 150 N axial load.
  • Results suggest the 5×5 mm extra-short implant enhances biomechanical stability under loading conditions.

Abstract

Background: In scenarios of limited bone height, extra-short implants offer a minimally invasive option. However, biomechanical behavior under functional loading remains critical for success. Objective: To evaluate stress distribution in cortical and cancellous bone, abutment, implant, and surrounding structures when two extra-short implants with straight abutments are subjected to axial load, using finite element analysis. Methods: 3D models of two extra-short implants (5×4 mm and 5×5 mm) with straight abutments were created using CATIA and analyzed using ANSYS Workbench. Axial forces of 150 N were applied. Von Mises stress values were recorded. Results: The 5×5 mm straight implant showed the lowest stress values in all components compared to the 5×4 mm implant. Stress was highest in cortical bone, followed by implant, abutment, crown, and cement. Conclusion: The larger-diameter short implant (5×5 mm) with a straight abutment demonstrated better stress distribution under axial loading, suggesting improved biomechanical stability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Nazirkar et al. (2025) studied this question.

synapsesocial.com/papers/68c1c63e54b1d3bfb60f2515https://doi.org/10.53555/ajbr.v28i3s.8214
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Influence of Different Implant Abutment Connection Types on the Stress Distribution in Standard and Short Implants and the Peripheral Bone: A Three-dimensional Finite Element Analysis2026
  2. 2Stress Distribution of Different Anterior Single Implants: A 3D Finite Element Analysis2024
  3. 3Stress distribution of an anteriorly placed single implant in different clinical scenarios: a 3D finite element analysis.2026
  4. 4A Comparative Evaluation of Stress Distribution Around Different Widths of Implant and Bony Interface in Function During Axial and Non-axial Loading: A Finite Element Analysis2024 · 5 citations
  5. 5Stress distribution in three-unit implant-supported prostheses with different abutment designs: a finite element analysis2026