PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 6, 2026Applied Physics Letters0 citations

Advanced null ellipsometry for ultrathin film thickness measurement

View Full Paper
HDHaotian DongCYChengyuan YaoZWZizheng Wang

Key Points

  • The study aims to enhance the accuracy of thickness metrology for ultrathin films using null ellipsometry.
  • Develops an error analysis for null ellipsometry-based film metrology
  • Accounts for detector noise and azimuthal rotation errors
  • Identifies optimal wavelength-incident-angle combinations for measurement
  • Conducts measurements on ultrathin SiO2 films
  • Achieves picometer-level measurement repeatability of 0.98 pm
  • Exhibits significant improvement over commercial ellipsometers
  • Confirms accuracy of null ellipsometry without stringent environmental controls

Abstract

Ultrathin films have emerged as a versatile functional platform for electronic, optical, and optoelectronic technologies, spanning semiconductors, displays, and next-generation energy devices. Accurate and highly robust thickness metrology underpins both fundamental and application-oriented studies of ultrathin films. By operating at an intensity-null condition, null ellipsometry delivers sub-nanometer thickness resolution and superior accuracy for static ultrathin film thickness metrology. However, conventional null ellipsometry exhibits a substantial performance mismatch with the trend toward atomically scaled film thicknesses, particularly in its inability to ensure picometer-level measurement repeatability. An error analysis approach for null ellipsometry-based film thickness metrology is established that explicitly accounts for detector noise and azimuthal rotation errors. By clarifying the wavelength- and incident-angle-dependent behavior of the thickness error, optimal wavelength-incident-angle combinations are identified that enable picometer-level measurement repeatability. Measurements on ultrathin SiO2 films demonstrate a minimum thickness-measurement repeatability of 0.98 pm, corresponding to an order-of-magnitude improvement over commercial ellipsometers. This result confirms that the proposed approach achieves picometer-level measurement repeatability without requiring stringent environmental control. This work establishes a new paradigm of null ellipsometry that enables highly robust metrology of ultrathin film thicknesses, holding great promise for both fundamental research and applications in emerging materials and advanced manufacturing.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dong et al. (2026) studied this question.

synapsesocial.com/papers/69faa28f04f884e66b5331c0https://doi.org/10.1063/5.0319919
Ask AI
Helpful
Bookmark
Share
View Full Paper