Mechanical Property Degradation Behavior and Fatigue Life Analysis of Corroded High-Strength Steel Wires

View Full Paper
GYGuilin YangDLDamin LuLJLili Jin

Key Points

  • This research aims to understand how corrosion affects the mechanical and fatigue properties of high-strength steel wires used in bridge cables.
  • Specimens of galvanized steel wires with varying mass loss rates were prepared through electrochemical corrosion.
  • Tensile and fatigue tests were systematically conducted to assess the mechanical properties and fatigue life.
  • A finite element model was developed based on the 3D scanning geometry to predict fatigue life.
  • The yield strength and tensile strength of corroded wires significantly degrade, while ductility shows severe deterioration.
  • Steel wires with less than 2.75% mass loss maintain favorable fatigue resistance at 360 MPa nominal stress amplitude.
  • Fatigue life decreases nonlinearly with increasing mass loss rates beyond 2.75%, with predictions matching experimental results.

Abstract

Investigating the effects of corrosion on the mechanical and fatigue properties of steel wires is critical for the safety assessment of bridge cable structures.This study focuses on high-strength galvanized steel wires used for bridge cables, with a diameter of 7 mm and a strength grade of 1770 MPa. Specimens with varying mass loss rates η were prepared by electrochemical corrosion method, and systematic tensile and fatigue tests were conducted to study the effects of corrosion on the fundamental mechanical properties and fatigue life of the steel wires. The results indicate that the elastic modulus of the steel wires decreases slightly with the increase of η but still meets the requirements of relevant standards. In contrast, the yield strength and tensile strength degrade significantly, while ductility is particularly susceptible to corrosion, showing more severe deterioration. When η is less than 2.75%, the corroded steel wires still maintain favorable fatigue resistance at a nominal stress amplitude of 360 MPa. Once η exceeds this threshold, their fatigue life decreases significantly in a nonlinear manner with increasing η. The fatigue life predicted by a finite element model (FEM) reconstructed based on the 3D scanning geometry of corroded steel wires and combined with the Abaqus/fe-safe module shows good agreement with the experimental results, indicating that this approach can provide a valuable reference for the durability assessment of bridge cables.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yang et al. (2026) studied this question.

synapsesocial.com/papers/6a0d50dcf03e14405aa9cfb6https://doi.org/10.3390/ma19102099
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Experimental and Numerical Study of the Fatigue Properties of Corroded Parallel Wire Cables2011 · 139 citations
  2. 2Mechanical Properties and Remaining Strength of Corroded Bridge Wires2004 · 80 citations
  3. 3The corrosion-fatigue measurement test of the Zn-Al alloy coated steel wire2020 · 43 citations
  4. 4Full-range fatigue life prediction model for corroded steel rebars: 3D pit-cracks coupling mechanism and validation2025 · 2 citations
  5. 5Random corrosion characteristics of high strength steel wire after 18 years of service and the numerical reconstruction method2023 · 16 citations