PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 17, 2026Animals0 citationsOpen Access

Reference Intervals for Trace Elements in Canine Plasma

View Full Paper
BLBelén LarránMLMarta López-AlonsoMMMarta Miranda

Key Points

  • The aim is to establish reference intervals for trace elements in canine plasma to aid in diagnosing and treating diseases.
  • Analyzed plasma samples from 140 dogs using inductively coupled plasma mass spectrometry.
  • Determined levels of 13 trace elements and established reference intervals (µg/L) for 12 elements.
  • Evaluated effects of factors such as sex, age, size, and breed on trace element concentrations.
  • Reference intervals were established for 12 trace elements, including Cu, Fe, and Zn.
  • 77% of samples showed cadmium below the limit of quantification.
  • Statistical differences in trace element concentrations were observed concerning sex, age, and size, but effects were generally weak.

Abstract

Trace elements are essential for organisms, and their involvement in diverse diseases is increasingly recognised. Interest is increasing in veterinary medicine, particularly in relation to canine diseases. However, reference intervals for trace elements in dogs remain scarce. Plasma samples from 140 dogs were analysed by inductively coupled plasma mass spectrometry to determine the levels of 13 trace elements. Reference intervals (µg/L) were established for the following 12 elements: As, 0.417–8.17; Co, 0.039–1.33; Cr, 2.41–13.3; Cu, 296–790; Fe, 846–3643; Hg, 0.235–2.33; Ni, 0.567–9.04; Mn, 1.90–7.28; Mo, 1.43–12.7; Pb, 0.285–2.82; Se, 200–434; and Zn, 415–1095. However, Cd was below the limit of quantification in 77% of the samples. No differences in trace element concentrations were observed in relation to breed or reproductive status. Statistically significant differences were found in relation to sex (Cu, Mo, Zn), age (Co, Cu, Mo, Mn, Se, Zn), and size (Cu, Mo, Se, Zn); however, the magnitude of these effects varied among elements and was generally weak. Nevertheless, these factors should be considered when assessing trace element status. These reference intervals constitute an important resource for both clinical evaluation and future research.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Larrán et al. (2026) studied this question.

synapsesocial.com/papers/696b2696d2a12237a9349da8https://doi.org/10.3390/ani16020264
Ask AI
Helpful
Bookmark
Share
View Full Paper