PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 20, 2026Journal of Clinical Ultrasound0 citations

Recognition of Normal Fetal Echocardiograms Based on an Explainable Denoising Deep Learning Model

View Full Paper
SSShuhao SongYLYuShan LiuGXGanqiong Xu

Key Points

  • The aim is to evaluate the GSCAViT model for accurately classifying normal fetal echocardiograms.
  • Conducted a retrospective analysis of 358 fetal cardiac ultrasound exams.
  • Utilized the GSCAViT model compared to baseline and enhanced models.
  • Implemented metrics such as accuracy, precision, recall, and F1 score for evaluation.
  • Employed SHAP for feature interpretation and assessed image quality metrics.
  • GSCAViT achieved an accuracy of 97.1% on validation and test sets.
  • Low error rates were recorded at 2.9%, 0.6%, 18.7%, and 27.1%.
  • SHAP visualizations confirmed the identification of key cardiac structures.
  • GSCAViT provided the highest contrast-to-noise ratio and peak signal-to-noise ratio results.

Abstract

ABSTRACT Purpose To evaluate the proposed explainable denoising deep learning model, Grouped Shared Convolutional Attention Vision Transformer (GSCAViT), for classifying normal fetal echocardiogram. Methods A retrospective study was conducted on 358 fetal cardiac ultrasound exams with a total of 2501 images. GSCAViT utilized seven echocardiograms and was compared against baseline and enhanced models using metrics including accuracy, precision, recall, F1 score. The SHAP method clarified key image features, and the denoising guided GSCA module was assessed through visual comparisons and image quality metrics. Results GSCAViT achieved an accuracy of 97.1%, 99.4%, 81.3%, 72.9% on the validation and three test sets. In addition, GSCAViT achieved low error rates of 2.9%, 0.6%, 18.7%, and 27.1%. To improve upon existing Vision Transformer based models and denoising modules, we propose the GSCAViT, which integrates a novel denoising‐guided GSCA module for enhanced image quality and interpretability. SHAP visualizations confirmed the model's ability to identify critical cardiac structures, while the denoising module enhanced image quality, yielding the highest contrast‐to‐noise ratio and peak signal‐to‐noise ratio values. Conclusion GSCAViT outperformed baseline and several enhanced models in classifying seven types of normal fetal echocardiograms, SHAP visualization enhanced the interpretability of classification, comparisons of visual effectiveness and image parameters confirmed the efficacy of the GSCA module.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Song et al. (2026) studied this question.

synapsesocial.com/papers/696f1a469e64f732b51ee8b2https://doi.org/10.1002/jcu.70183
Ask AI
Helpful
Bookmark
Share
View Full Paper