January 22, 2026Sensors0 citationsOpen Access

Development of a Robot-Assisted TMS Localization System Using Dual Capacitive Sensors for Coil Tilt Detection

View Full Paper
COCzaryn Diane Salazar OmpicoJBJulius Noel BanayoYMYamato Mashio

Key Points

  • The aim is to develop a novel robot-assisted system for accurate coil placement in transcranial magnetic stimulation.
  • Design of a markerless robotic-assisted TMS system using a 3D depth camera and textile capacitive sensors.
  • Utilization of facial landmarks for estimating motor cortex location without external markers.
  • Implementation of dual textile-sensor suspension for contact control and coil tilt estimation.
  • Evaluation with experimental trials involving multiple participants to assess reliability and effectiveness.
  • Reliable targeting of the motor cortex was achieved with valid motor evoked potentials in most trials after calibration.
  • Peak MEP amplitudes were observed near balanced sensor readings in 80% of tilt-verification trials.
  • The system adheres to international safety standards for human-robot interaction.

Abstract

Transcranial Magnetic Stimulation (TMS) is a non-invasive technique for neurological research and therapy, but its effectiveness depends on accurate and stable coil placement. Manual localization based on anatomical landmarks is time-consuming and operator-dependent, while state-of-the-art robotic and neuronavigation systems achieve high accuracy using optical tracking with head-mounted markers and infrared cameras, at the cost of increased system complexity and setup burden. This study presents a cost-effective, markerless robotic-assisted TMS system that combines a 3D depth camera and textile capacitive sensors to assist coil localization and contact control. Facial landmarks detected by the depth camera are used to estimate the motor cortex (C3) location without external tracking markers, while a dual textile-sensor suspension provides compliant “soft-landing” behavior, contact confirmation, and coil-tilt estimation. Experimental evaluation with five participants showed reliable C3 targeting with valid motor evoked potentials (MEPs) obtained in most trials after initial calibration, and tilt-verification experiments revealed that peak MEP amplitudes occurred near balanced sensor readings in 12 of 15 trials (80%). The system employs a collaborative robot designed in accordance with international human–robot interaction safety standards, including force-limited actuation and monitored stopping. These results suggest that the proposed approach can improve the accessibility, safety, and consistency of TMS procedures while avoiding the complexity of conventional optical tracking systems.