January 22, 2026JACOW0 citationsOpen Access

Machine vision cameras for beam spot analysis

View Full Paper
MBMichael BreeTBT. BattenWJWahhaj Javed

Key Points

  • The research aims to develop a CCD camera system for effective beam spot analysis at the Canadian Light Source synchrotron.
  • Implemented EPICS-based imaging system using inexpensive CCD cameras.
  • Replaced analog beam diagnostic cameras with advanced digital technology.
  • Enabled real-time computation of beam parameters during operation.
  • Successfully computed beam parameters including strength and centroid in real time.
  • Identified ellipticity and eccentricity of beam spots.
  • Facilitated image saving for post-processing, enhancing analysis capabilities.

Abstract

The Canadian Light Source is a third generation synchrotron which supports 22 operational beamlines. A project to replace all beam diagnostic analog cameras with CCD cameras was initiated in 2020. Over time this project has been expanded to include beam analysis capabilities. We present an EPICS-based imaging system that uses inexpensive CCD cameras. The system computes beam parameters including strength, centroid, ellipticity, eccentricity, and angle. Analysis is performed in real time, and images can also be saved for post processing. Features, implementation details, obstacles and long term plans will be discussed.