PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 22, 2026Smart Cities0 citationsOpen Access

Smart Sensing in Italian Historic City Centers: The Liminal Environmental Monitoring System (LEMS)

View Full Paper
VDValentina DiolaitiLSLeonardo SollazzoGMGiulio Mangherini

Key Points

  • The aim is to develop and implement a monitoring system for environmental conditions in semi-outdoor spaces of historic city centers.
  • Development of the Liminal Environmental Monitoring System (LEMS) using a custom data acquisition board.
  • Integration of multiple analogue and digital sensors and a daisy-chain communication using MODBUS RS485.
  • Deployment in the cloister of Palazzo Costabili, Ferrara, to monitor air temperature, humidity, and solar irradiance.
  • LEMS effectively captures variations in air temperature, relative humidity, and solar irradiance.
  • Simulation-derived annual solar-shading indicators assist in interpreting irradiance data.
  • The system is deemed viable for microclimate monitoring in heritage contexts.

Abstract

Historic city centers host dense ensembles of heritage buildings where conservation goals must coexist with sustainable and smart urban development, yet the semi-outdoor “liminal” spaces of these complexes, such as cloisters, loggias and courtyards, are rarely included in microclimate monitoring networks. This study develops and tests the Liminal Environmental Monitoring System (LEMS), a flexible environmental data acquisition architecture designed for long-term monitoring in such spaces. The LEMS is based on a custom, low-cost data acquisition board able to handle multiple analogue and digital sensors, combined with a daisy-chain communication layout using the MODBUS RS485 protocol and a commercial datalogger as master, in order to meet the technical and visual constraints of historic buildings. Board calibration and sensor characterisation are reported, and the system is deployed in the cloister of Palazzo Costabili, a renaissance complex in the historic city center of Ferrara (Italy). This case study illustrates how the LEMS captures spatial and temporal variation in air temperature, relative humidity and solar irradiance and how an annual solar-shading indicator derived from 3D ray-tracing simulations supports the interpretation of irradiance measurements. The results indicate that the LEMS is a viable tool for heritage-compatible microclimate monitoring and can be adapted to other historic courtyards and loggias.