PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 23, 2026Journal of Veterinary Internal Medicine0 citationsOpen Access

Development and validation of the Chiari-like malformation and syringomyelia evaluation: the CHASE questionnaire

View Full Paper
AVAmanda ValentinoSMSarah A MooreSFStuart Fitzgerald

Key Points

  • The aim is to develop and validate the CHASE questionnaire for quantifying clinical signs of Chiari-like malformation and syringomyelia in dogs.
  • Developed CHASE questionnaire using iterative sampling design
  • Conducted a double-blinded, randomized, crossover trial with pregabalin and placebo
  • Performed physical examinations, quantitative sensory testing, and quality of life assessments alongside CHASE questionnaire
  • Established reliability and normal scores using healthy dogs
  • CHASE scores were significantly higher in CM/SM dogs compared to healthy dogs (15.3 vs. 1.4)
  • Scores were moderately repeatable from screening to baseline in CM/SM dogs
  • Pregabalin treatment significantly reduced CHASE scores compared to placebo
  • CHASE demonstrated strong internal consistency (α = 0.89) with good sensitivity (63%) and specificity (76%) for treatment outcomes

Abstract

Abstract Background Chiari-like malformation (CM) and syringomyelia (SM) in dogs are associated with signs of neuropathic pain and itch, which are difficult to quantify reliably. Hypothesis/Objectives Develop and validate the Chiari-like malformation and syringomyelia evaluation (CHASE) questionnaire to quantify owners’ assessments of clinical signs of CM/SM in their dogs. Animals Twenty client-owned healthy dogs and 30 CM/SM affected dogs. Methods The CHASE questionnaire was developed using an iterative sampling design, reliability and normal scores were established in healthy dogs. A double-blinded, randomized, crossover study design was conducted using pregabalin and placebo, with CHASE as the primary outcome. Physical and neurologic examinations, activity monitors, quantitative sensory testing (QST), and quality of life assessments (QOL) were performed alongside the CHASE questionnaire at each time point. Results Baseline CHASE scores were significantly higher in CM/SM dogs compared with healthy dogs (15.3 ± 4.8 vs. 1.4 ± 1.8; P .01), with score ranges of 6-24 and 0-6, respectively. The CHASE scores in CM/SM dogs were moderately repeatable from screening (15.1 ± 4.4) to baseline (15.1 ± 4.7) and decreased significantly with pregabalin compared with baseline and placebo (P 0.001 and P 0.03). The questionnaire had strong internal consistency (α = 0.89) and differentiated pregabalin from placebo with 63% sensitivity and 76% specificity (area under the curve = 0.67). No significant differences in QOL, QST, or activity levels were identified. Conclusions and clinical importance We validated the use of the CHASE questionnaire to quantify clinical signs associated with CM/SM and distinguish treatment outcomes when other assessments failed.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Valentino et al. (2026) studied this question.

synapsesocial.com/papers/69730f34c8125b09b0d1f127https://doi.org/10.1093/jvimsj/aalaf040
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Development and psychometric testing of an instrument designed to measure chronic pain in dogs with osteoarthritis2007 · 249 citations
  2. 2Pharmacokinetics of single-dose oral pregabalin administration in normal dogs2009 · 72 citations
  3. 3Development of the short-form Glasgow Composite Measure Pain Scale (CMPS-SF) and derivation of an analgesic intervention score2007 · 531 citations
  4. 4Association of Chiari malformation type I and tethered cord syndrome: preliminary results of sectioning filum terminale2009 · 120 citations
  5. 5CHARACTERISTICS OF CEREBROSPINAL FLUID FLOW IN CAVALIER KING CHARLES SPANIELS ANALYZED USING PHASE VELOCITY CINE MAGNETIC RESONANCE IMAGING2009 · 70 citations