PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 2, 2026Journal of Laboratory Physicians0 citationsOpen Access

Titration of monoclonal antibodies and stability of tandem dyes in cocktail preparation for flow cytometry processing

View Full Paper
SKSherin KoodathilPMPrabhu Manivannan

Key Points

  • This study aimed to optimize the volumes of pre-titrated antibodies and assess the stability of tandem dyes in cocktail preparations for flow cytometry.
  • Conducted titration of various fluorochrome-conjugated antibodies.
  • Prepared antibody cocktails including specific fluorochromes.
  • Evaluated tandem dye stability using lyophilized cells over five days and four weeks.
  • Applied statistical analysis focusing on mean fluorescent intensity and percentage of positive cells.
  • Antibody titration reduced final antibody volume by 77%, lowering testing costs.
  • Coefficient of variation values remained below 5% during all assessments, confirming stability.
  • Tandem dyes in the cocktail were stable for up to four weeks.

Abstract

Objectives: Tandem dyes are routinely used in multicolor flow cytometry (MFC) and consist of two fluorochromes, one donor and one acceptor. Antibody cocktails for various panels are prepared by combining the pre-titrated volumes of each fluorochrome-conjugated antibody. As the performance and stability of tandem dyes may deteriorate over time, this study aimed to optimize antibody titration volumes and assess the stability of pre-titrated tandem dyes in cocktail preparations. Materials and Methods: This was a quantitative study in which titration was performed, and the prepared antibody cocktail comprised cytoplasmic myeloperoxidase-Fluorescein Isothiocyanate (FITC), cytoplasmic cluster of differentiation (cCD) 79a-Phycoerythrin (PE), CD19-energy coupling dye (ECD), CD34-phycoerythrin-cyanin (PC) 5.5, cCD3-PC7, CD45-allophycocyanin (APC) 700, CD7-APC750, sCD3-pacific blue (PB), and human leucocyte antigen - D region related (HLA-DR isotype) tagged with krome orange (KO). CytoComp TM lyophilized cells were used to evaluate tandem dye stability daily for five days and weekly for four weeks. The stain-lyse-wash procedure was used, and data acquisition and analysis were performed in the Navios TM flow cytometer. Statistical analysis: The mean fluorescent intensity and percentage of positive cells were recorded for most of the antibodies in the cocktail. A coefficient of variation (CV) value of >5% was considered statistically significant, indicating the degradation of tandem dyes. Results: Antibody titration reduced the final antibody volume by 77%, reducing the cost per test. CV values remained below 5% during all assessments, confirming cocktail stability for up to four weeks when tested with lyophilized cells. Conclusions: The pre-titrated antibody cocktail was cost-effective and stable for up to four weeks, including tandem dyes, making it suitable for routine flow cytometric applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Koodathil et al. (2026) studied this question.

synapsesocial.com/papers/6980fc55c1c9540dea80e297https://doi.org/10.25259/jlp_251_2025
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Tandem Dyes: Stability in cocktails and compensation considerations2013 · 17 citations
  2. 2Flow cytometry controls, instrument setup, and the determination of positivity2006 · 364 citations
  3. 3Considerations for the control of background fluorescence in clinical flow cytometry2009 · 254 citations
  4. 4Flow cytometry APC‐tandem dyes are degraded through a cell‐dependent mechanism2009 · 46 citations
  5. 5Guidelines on the use of multicolour flow cytometry in the diagnosis of haematological neoplasms2014 · 97 citations