PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 2, 2026Magnetic Resonance in Medicine0 citationsOpen Access

On‐Scanner Correction of Gradient Nonlinearity Bias for Accurate Assessment of Diffusion Heterogeneity Across Bone Sites in Myelofibrosis Patients

View Full Paper
DMDariya MalyarenkoBRBrian D. RossJPJohannes Peeters

Key Points

  • The research aims to enhance the accuracy of ADC measurements across various bone marrow sites in myelofibrosis patients.
  • Implemented vendor-provided ADC gradient nonlinearity correction for 41 myelofibrosis subjects.
  • Assessed bias correction across defined bone marrow regions including femoral trochanter and spine.
  • Evaluated bias variability using Bland–Altman analysis on longitudinal scans.
  • Compared ADC values with and without GNC in subjects with MF grade greater than 0.
  • Analyzed GNC effect on ADC heterogeneity trends with paired t-test.
  • Observed bias in ADC measurements ranged from -10% to +8.4% across bone sites.
  • Intra-subject median range for bias was 13.7%.
  • Longitudinal scan positioning contributed ±4.2% bias variability.
  • GNC significantly improved ADC uniformity and highlighted biological heterogeneity.
  • Significant differences were noted in ADC between trochanters and edge vertebrae (p = 0.007).

Abstract

ABSTRACT Purpose To improve accuracy of apparent diffusion coefficient (ADC) measurement across different bone‐marrow (BM) sites for myelofibrosis (MF) patients. Methods Vendor‐provided ADC gradient nonlinearity correction (GNC) was implemented for 41 MF study subjects on a 3T clinical scanner. The degree of bias correction was assessed on b‐maps across the BM regions‐of‐interest defined for femoral trochanter, posterior ilium and spine vertebrae of all subjects. Bias variability from subject repositioning was evaluated for five subjects with longitudinal scans using Bland–Altman analysis. BM ADC with and without GNC were compared in 22 subjects with MF grade > 0 (iliac fat fraction < 40%). The GNC effect on ADC heterogeneity trends across bone sites was assessed using paired t‐test and correlation to MF‐grade. Results The observed bias was substantial across BM sites ranging from −10% for edge vertebrae to +8.4% for trochanter across all subjects with a 13.7% intra‐subject median range. The effect of irreproducible positioning in longitudinal scans was ±4.2% bias (95% limits‐of‐agreement) with range of ±8.5% (highest for L1 and L5). By removing bias, GNC improved ADC accuracy and longitudinal reproducibility and emphasized biological heterogeneity for femoral trochanter versus ilium and edge vertebrae (T11‐L1, L5, and S1). GNC revealed significant ADC differences between trochanters and edge vertebrae ( p = 0.007), while edge vertebrae and ilium ADC became more uniform ( p = 0.07), with heterogeneity and values correlated to MF‐grade. Conclusion On‐scanner correction of gradient nonlinearity bias in bone marrow ADC reduces technical nonuniformity and variability and allows accurate and reproducible characterization of heterogeneous disease for myelofibrosis patients.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Malyarenko et al. (2026) studied this question.

synapsesocial.com/papers/6980feb9c1c9540dea8111bahttps://doi.org/10.1002/mrm.70273
Ask AI
Helpful
Bookmark
Share
View Full Paper