Euclid preparation. LXXX. Overview of Euclid infrared detector performance from ground tests

View Full Paper
ECEuclid CollaborationBKB. KubikRBR. Barbier

Key Points

  • This work aims to evaluate and characterize the performance of the Euclid infrared detectors before launch.
  • Conducted ground characterisation campaigns for infrared detectors.
  • Performed measurements of various pixel properties including dark current and quantum efficiency.
  • Developed data acquisition and quality check software for accurate analysis.
  • Defined measurement protocols for evaluating pixel performance.
  • Less than 0.2% of pixels were classified as non-functioning.
  • 95% of pixels achieved a quantum efficiency greater than 80% across the spectral range.
  • Reset noise approximated at 23 ADU rms, with minimal interpixel coupling under 1%.
  • Deviation from linear response was less than 5% for 95% of pixels at signal levels up to 80 ke-.

Abstract

This paper describes the objectives, design, and findings of the pre-launch ground characterisation campaigns of the Euclid infrared detectors. The aim of the ground characterisations is to evaluate the performance of the detectors, to calibrate the pixel response, and to derive the pixel response correction methods. The detectors have been tested and characterised in the facilities set up for this purpose. The pixel properties, including baseline, bad pixels, quantum efficiency, inter pixel capacitance, quantum efficiency, dark current, readout noise, conversion gain, response non-linearity, and image persistence were measured and characterised for each pixel. We describe in detail the test flow definition that allows us to derive the pixel properties and we present the data acquisition and data quality check software implemented for this purpose. We also outline the measurement protocols of all the pixel properties presented and we provide a comprehensive overview of the performance of the Euclid infrared detectors as derived after tuning the operating parameters of the detectors. The main conclusion of this work is that the performance of the infrared detectors Euclid meets the requirements. Pixels classified as non-functioning accounted for less than 0. 2% of all science pixels. The interpixel capacitance (IPC) coupling is minimal, the cross-talk between adjacent pixels is less than 1% between adjacent pixels, and 95% of the pixels show a quantum efficienty (QE) greater than 80% across the entire spectral range of the Euclid mission. The conversion gain is approximately 0. 52, ADU/e^-, with a variation of less than 1% between channels of the same detector. The reset noise is approximately equal to 23 ADU rms after reference pixel correction. The readout noise of a single frame is approximately e^- rms while the signal estimator noise is measured at 7, e^- rms in photometric mode and 9, e^- rms in spectroscopic acquisition mode. The deviation from linear response at signal levels up to 80, ke^- is less than 5% for 95% of the pixels. Median persistence amplitudes are less than 0. 3% of the signal, though persistence exhibits significant spatial variation and differences between detectors.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Collaboration et al. (2025) studied this question.

synapsesocial.com/papers/698c1c33267fb587c655e6a0https://doi.org/10.5167/uzh-291174
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1preparation2026
  2. 2Euclid : Early Release Observations – Programme overview and pipeline for compact- and diffuse-emission photometry2025 · 45 citations
  3. 3Performance of the image persistence model for Euclid infrared detectors2024
  4. 4Euclid: IV. The NISP Calibration Unit2025
  5. 5Euclid2024 · 6 citations