February 12, 2026Advanced Energy Materials0 citationsOpen Access

Selective Charge Extraction Allows Fast Photomultiplication and Imaging in Rigid and Ultra‐Flexible SWIR Organic Photodiodes

View Full Paper
MBMatilde BrunettaZQZhuoran QiaoDNDavide Nodari

Key Points

  • To enhance the performance of organic photodiodes for bioimaging applications by advancing their responsiveness in the near-infrared spectrum.
  • Utilized a donor:acceptor ratio in the bulk heterojunction of photodiodes
  • Used the NIR polymer TQ-3T with nonfullerene acceptor Y6
  • Performed bending tests on ultrathin flexible photodiodes for durability
  • Measured external quantum efficiency and response times at various wavelengths
  • Achieved external quantum efficiency over 1100% at 840 nm and 31% at 1100 nm at -10 V
  • Demonstrated fast response times of 73 µs
  • Flexible PM-OPDs maintained performance after 1000 bending cycles
  • Showed capability as a flexible pulse oximeter and image sensor for vein recognition

Abstract

ABSTRACT Expanding the absorption window of organic photodiodes (OPDs) over the 1000 nm benchmark is essential for bioimaging and medical applications. However, progressing into this wavelength range has proven to be a challenging task due to the scarcity of near‐infrared (NIR) semiconducting polymers and small molecules with suitable energy alignment and processability. OPDs based on low‐bandgap donor polymers generally present low responsivities and, therefore, low detectivities in the NIR. Photomultiplication (PM) has been introduced as a promising strategy to increase the external quantum efficiency (EQE) above unity. However, its application has been mainly limited to OPDs operating in the visible range and with response speeds within the millisecond range. In this work, we present PM‐OPDs utilizing an equal donor (D):acceptor (A) ratio in the bulk heterojunction photoactive layer. This changes the common understanding of PM‐OPDs, in which heavily unbalanced D:A ratios were needed to impose trap‐assisted charge tunnelling injection at high reverse bias. Here, the NIR polymer TQ‐3T was used with nonfullerene acceptor Y6. PM‐OPDs with an EQE of above 1100% at 840 nm and 31% at 1100 nm at ‐10 V, and fast response times of 73 µs were achieved. We also demonstrate ultrathin (<3 µm) flexible PM‐OPDs based on the TQ‐3T:Y6 blend without any drop in performance compared to rigid samples with a stable dark current density after 1000 bending cycles. Finally, we demonstrate an application of the PM‐OPD as a flexible and pulse oximeter and large‐area image sensor for accurate vein recognition.