PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 14, 2026Scientific Reports0 citationsOpen Access

A lightweight residual dilated temporal transformer block for ECG classification on edge devices

View Full Paper
GGG. Antoni GracySPSheena Christabel Pravin

Key Points

  • To develop a lightweight deep learning model for ECG classification on edge devices that balances accuracy and efficiency.
  • Proposed a residual dilated temporal transformer block designed for edge deployment.
  • Utilized data augmentation techniques like SMOTE and jitter noise for class balance.
  • Integrated channel-wise attention and positional encoding in the architecture.
  • Achieved 99.34% classification accuracy.
  • Demonstrated strong performance with a Matthews Correlation Coefficient of 0.9891.
  • Maintained a lightweight model size of 692K parameters and low computational cost.

Abstract

Wearable devices play a crucial role in healthcare by enabling continuous monitoring of vital physiological signals such as ECG, heart rate, respiration, body temperature, oxygen saturation, blood pressure, and activity metrics. These systems facilitate early detection and ongoing management of cardiovascular diseases, extending clinical capabilities beyond traditional settings. However, since the wearables are continually powered, there are stringent constraints on energy efficiency, processing latency, and data privacy. While cloud-based inference introduces high communication overhead, on-device deep learning raises computational and thermal challenges, demanding lightweight, accurate, and privacy-aware solutions. In this work, we propose a highly efficient and resource conscious deep learning model for ECG classification of three clinically significant classes: Arrhythmia (ARR), Congestive Heart Failure (CHF), and Normal Sinus Rhythm (NSR). The model is specifically optimized for deployment on edge devices. It combines residual dilated convolutions with a deep Transformer architecture enhanced by positional encoding, channel-wise attention (SE blocks), and class balanced data augmentation using SMOTE and jitter noise. Despite having only 692K parameters (2.64 MB) and approximately 0.234 GFLOPs, the model achieves 99.34% classification accuracy, Macro AUROC of 0.9996, Cohen’s Kappa of 0.9891, and Log Loss of 0.0495. It further demonstrates strong generalization with a Hamming Loss of 0.0062 and Matthews Correlation Coefficient (MCC) of 0.9891 on the benchmark ECG dataset. The proposed method achieves an exceptional trade off between accuracy, model complexity, and inference speed, making it well suited for real-time, privacy preserving cardiac monitoring on low power, latency constrained platforms such as wireless body sensor networks and wearable edge devices.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gracy et al. (2026) studied this question.

synapsesocial.com/papers/698fd276306598e8538de9adhttps://doi.org/10.1038/s41598-026-35531-4
Ask AI
Helpful
Bookmark
Share
View Full Paper