PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 19, 2026Scientific Reports0 citationsOpen Access

Advanced electrical diagnostics for monitoring soil contamination: a laboratory-based assessment approach

View Full Paper
MMMostafa MoawadMGMohamed M. GomaaAEAhmed Elshenawy

Key Points

  • This research aims to assess how electrical measurements can monitor soil contamination, particularly from oil and PCBs.
  • Laboratory-based assessment of shale contaminated by oil and PCBs
  • Measurement of electrical parameters including dielectric constant, conductivity, and impedance
  • Testing varied shale sample conditions: natural, cracked, and synthetic
  • Contamination levels and saturations measured from dry to fully saturated samples
  • Increased contamination leads to decreased electrical conductivity and dielectric constant
  • Distinct behaviors noted in cracked samples due to contaminant penetration
  • Electrical measurements provide a preliminary screening tool for monitoring soil contamination
  • Method offers a non-invasive, cost-effective approach for environmental assessments
  • Findings align with sustainable development goals of Egypt vision 2023

Abstract

Soil contamination is one of the vital environmental challenges the world encounters. This study demonstrates the potential of electrical measurements in controlling and limiting the spread of contamination through soils. The current laboratory samples represent shale contaminated by oil containing polychlorinated biphenyls (PCBs). PCBs are serious risk to living organisms, particularly when they reach soils and aquifers. This study aims to show how electrical measurements can serve as a monitor for soil contamination and oil seepage. This contaminant is regarded as a semi-insulating material, whereas shale is supposed as a semi-conducting material. Different cases of shale samples (natural core, cracked core, and synthetic) and saturations (dry to fully saturated samples) with this contaminant were used. Electrical parameters (dielectric constant, conductivity, and impedance plane), for shale samples collected from Bani-Swef area, were measured. Therefore, samples (shale) were contaminated with oil at various contamination levels and concentrations to measure the electrical responses. These electrical measurements were performed at a frequency range starting from 1 mHz to 100 kHz. The results reveal that when levels of contamination increase, electrical conductivity and dielectric constant decrease for all sample cases. The contaminant reflects its insulator electrical characteristics. The laboratory measurements show reasonable results for natural and synthetic samples, while those for cracked samples exhibit abnormal behaviour, because the contaminant penetrates through the fractures and causes some distortion in the electrical readings. The electrical measurements show that it can be used as a preliminary screening step for monitoring soil contamination, particularly for oil seepage cases. It may offer a high-quality functional technique that is both cost-effective and non-invasive. This method may allow for a fast evaluation and assist as a massive environmental monitoring tool. This approach aligns with the sustainable development goals of Egypt vision 2023.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Moawad et al. (2026) studied this question.

synapsesocial.com/papers/6996712d80e1323b05ec03b2https://doi.org/10.1038/s41598-026-37447-5
Ask AI
Helpful
Bookmark
Share
View Full Paper