February 19, 2026Journal of VitreoRetinal Diseases1 citationsOpen Access

Scleral Fixation of Intraocular Lenses: Outcomes From MA60AC Intraocular Lens Fixation With a 10-0 Prolene Suture vs Akreos Intraocular Lens Fixation With a Polytetrafluoroethylene (Gore-Tex) Suture

View Full Paper
GGGuilherme Marge De Aquino GuedesDLDaniel Lani LouzadaRBRodrigo Brant

Key Points

  • This study aims to compare the effectiveness and safety of two scleral fixation techniques for intraocular lenses.
  • Retrospective selection of patients undergoing pars plana vitrectomy from January 2019 to July 2021.
  • Outcomes evaluated included intraocular pressure, subjective refraction, corneal topography, and complications.
  • Participants followed for at least 6 months and invited for a clinic visit to assess procedures.
  • No statistically significant differences were found between the Akreos plus Gore-Tex and MA60AC plus Prolene groups.
  • Both techniques demonstrated similar refractive outcomes and postoperative complications.
  • Overall safety and efficacy of both scleral fixation methods were comparable.

Abstract

Purpose: To compare the outcomes of intraocular lens (IOL) scleral fixation using Akreos (Bausch + Lomb) lenses with polytetrafluoroethylene (Gore-Tex CV-8, W.L. Gore & Associates) sutures vs 3-piece IOLs (Alcon MA60AC) with 10-0 Prolene (Ethicon, a Johnson & Johnson Company) sutures. Methods: Patients undergoing pars plana vitrectomy between January 2019 and July 2021 were retrospectively selected regardless of the technique used. Patients who completed at least 6 months of follow-up were invited to a new clinic visit to evaluate outcomes of their procedures. The protocol included intraocular pressure assessment using a Goldmann tonometer, subjective refraction, corneal topography with a Pentacam HR (Oculus, Optikgeräte GmbH), IOL decentration assessment on biomicroscopy via slitlamp, and optic disc cupping evaluation by indirect ophthalmoscopy. Complications such as corneal edema, ocular hypertension, hypotony, hyphema, IOL decentration, cystoid macular edema, vitreous hemorrhage, suture breakage, retinal detachment, or uveitis–glaucoma–hyphema syndrome were investigated. Results: A total of 20 eyes from 20 participants were classified into 2 groups according to surgical technique: Akreos plus GoreTex (n=11) or MA60AC plus Prolene (n=9). The results showed no statistically significant differences between the 2 groups in terms of refractive outcomes, postoperative complications, or demographic variables, suggesting both techniques provide similar efficacy and safety. Conclusions: Both the Akreos with Gore-Tex and MA60AC with Prolene scleral fixation techniques are effective and safe for patients requiring IOL implantation in the absence of adequate capsular support. Further research is needed to solidify these observations and guide future clinical decisions.