PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 19, 2026Atmospheric measurement techniques0 citationsOpen Access

An intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments

LTLoren TempleSYStuart YoungTBThomas J. Bannan

Key Points

  • This research aims to compare different instruments for measuring sulfur dioxide (SO2) concentrations in marine environments.
  • Conducted measurements of SO2 using LIF, PF, and I−CIMS instruments aboard the UK FAAM research aircraft.
  • Assessed the performance of each instrument in both remote and polluted marine environments.
  • Compared limit of detection and response times for each instrument.
  • LIF demonstrated superior sensitivity with a limit of detection of 0.07 ppb, while PF had a limit of 0.4 ppb.
  • Both LIF and PF showed good correlation in high SO2 concentration plumes.
  • I−CIMS faced challenges with interference but correlated well with LIF and PF in polluted conditions.
  • LIF and I−CIMS had faster response times compared to the PF analyser.

Abstract

Abstract. The University of York's laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) analyser and iodide chemical ionisation mass spectrometer (I−CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes, the LIF instrument and PF analyser compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3σ) of 0.07 ppb at 10 s compared with 0.4 ppb for the PF analyser. Quantification of SO2 using I−CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air masses. A comparison of response time was also made, for which the I−CIMS and LIF instrument proved much faster than the PF analyser with 3 e-folding times of 0.6, 2 and 17 s respectively. This work demonstrates the importance of sensitive instrumentation like the LIF system for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Temple et al. (2026) studied this question.

synapsesocial.com/papers/6996a887ecb39a600b3ef54bhttps://doi.org/10.5194/amt-19-1165-2026
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1An intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments2025
  2. 2A sensitive method for atmospheric sulfur dioxide determination by reaction cell inductively coupled plasma mass spectrometer2025
  3. 3Quantitative Remote Sensing of Sulfur Dioxide Emissions from Industrial Plants Using Passive Fourier Transform Infrared (FTIR) Spectroscopy2025
  4. 4Retrieval of vertical concentration profiles of SO2 using the IASI satellite instrument2024
  5. 5Laser based observations of key inorganics (LOKI) on-board the UK research aircraft2024