PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 21, 2026Procedia Structural Integrity0 citationsOpen Access

Diagonal compression testing of FRCM-Strengthened Calcarenite masonry panels: DIC Analysis and Simplified Numerical Modelling

View Full Paper
MLMarielisa Di LetoGSGiuseppe SalaLPLorenzo Pace

Key Points

  • Assess the structural behavior of calcarenite masonry panels strengthened with FRCM systems during diagonal compression testing.
  • Conducted diagonal compression tests on calcarenite masonry panels strengthened with two FRCM solutions: glass fibers and carbon fibers.
  • Utilized Digital Image Correlation (DIC) techniques for full-field strain and displacement measurements.
  • Developed a simplified numerical model calibrated with experimental data to simulate mechanical responses.
  • Demonstrated differences in shear strength between glass-fiber and carbon-fiber strengthened panels.
  • Analyzed crack propagation and failure modes influenced by the type of FRCM used.
  • Validated the numerical model against experimental findings for enhanced precision in predicting behavior.

Abstract

Masonry structures made of calcarenite are common in many historical buildings, especially in Mediterranean regions. These structures often exhibit poor mechanical performance, particularly in resisting lateral loads, due to the inherent weakness of the stone and the aging of mortar joints. Masonry panels are among those elements intended to have load-bearing capacity for vertical loads and subject to horizontal actions resulting from earthquake action. Indeed, recent seismic events have highlighted their vulnerability when it comes to shear stresses acting in the plane of the panel. In recent years, Fabric-Reinforced Cementitious Matrix (FRCM) systems have emerged as a promising solution for the structural strengthening of existing masonry, offering advantages such as compatibility with historical materials, reversibility, and good mechanical performance. However, the wide range of materials available for reinforcement requires a careful assessment to determine the most suitable solution based on the characteristics of the substrate. This study investigates the structural behaviour of calcarenite masonry panels strengthened with FRCM systems under diagonal compression testing. Two FRCM solutions are compared: one employing glass fibres and the other carbon fibres. A key objective of the study is to highlight the importance of selecting the appropriate strengthening system based on the characteristics of the substrate material. The experimental campaign evaluates the shear performance of the panels, employing Digital Image Correlation (DIC) techniques to obtain full-field strain and displacement data with high spatial resolution. The influence of the different strengthening systems on crack propagation, failure modes, and shear strength is analyzed in detail. Additionally, a simplified numerical model is developed and calibrated using experimental data to simulate the mechanical response of both unreinforced and FRCM-strengthened specimens.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Leto et al. (2026) studied this question.

synapsesocial.com/papers/69994b01873532290d01f482https://doi.org/10.1016/j.prostr.2025.12.090
Ask AI
Helpful
Bookmark
Share
View Full Paper