PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 21, 2026Journal of Pediatric Intensive Care0 citationsOpen Access

Terminal Withdrawal of Mechanical Ventilation in a PICU

View Full Paper
JBJohn Scott BairdNPNatasha Z. PirachaMLMax E. Lindeman

Key Points

  • To assess the time-to-death following terminal withdrawal of mechanical ventilation in pediatric patients.
  • Conducted a retrospective case series analysis of pediatric patients in a PICU from 2015 to 2020.
  • Reviewed cases of terminal withdrawal of mechanical ventilation among 222 PICU deaths.
  • Analyzed associations between time-to-death and factors like age and mechanical ventilation duration.
  • 53 patients underwent terminal withdrawal of mechanical ventilation.
  • More than 90% of patients died within 24 hours; specifically, 37 patients died in less than 1 hour.
  • Time-to-death was significantly affected by concurrent withdrawal of cardiac support in patients.

Abstract

Objectives: Data regarding a terminal withdrawal of mechanical ventilation in pediatric patients, in particular the time-to-death, would be helpful to family and hospital staff. Methods: This retrospective case series will review the terminal withdrawal of mechanical ventilation in PICU patients at our hospital between 2015 and 2020. Results: There were 222 PICU deaths and 53 of these patients died following a terminal withdrawal of mechanical ventilation. The time-to-death was patients, from 1 to 24 hours in 12 patients, and >24 hours in 4 patients. Neither age nor the duration of mechanical ventilation prior to terminal withdrawal of mechanical ventilation was associated with time-to-death. Terminal withdrawal of mechanical ventilation was complicated by concurrent withdrawal of cardiac support devices in 9 patients and by a recent cardiac arrest in 3 patients (1 of whom also had a cardiac support device withdrawal), and the time-to-death for these 11 patients was less than one hour (p=0.01 vs. all others). The time-to-death for those without concurrent withdrawal of cardiac support devices or recent cardiac arrest was shorter in those with a higher fraction of inspired oxygen but was not associated with positive end expiratory pressure. Conclusions: Time-to-death following a terminal withdrawal of mechanical ventilation was less than a day in more than 90% of our patients and was not associated with patient age or the duration of mechanical ventilation. However in patients without a recent cardiac arrest or concurrent withdrawal of cardiac support devices nearly one in ten survived a terminal withdrawal of mechanical ventilation for more than a day, while those with a recent cardiac arrest or concurrent withdrawal of cardiac support devices survived for less than an hour.