February 22, 20260 citationsOpen Access

Swiss national cardiac device registry: Changing trends in implantation procedures over the last two decades

View Full Paper
NMNadine MolitorAAAngelo AuricchioEDEtienne Delacrétaz

Key Result

Pacemaker procedures doubled and ICD procedures tripled in Switzerland over 20 years; pacemaker patient age rose, ICD patient age remained stable, infections unchanged.

Key Points

  • To analyze trends in implantation procedures of cardiac devices in Switzerland over the past 20 years.
  • Analyzed SwissEPnet database from January 2003 to December 2022
  • Examined statistics for pacemakers and ICD procedures
  • Compared patient demographics and procedure details over time
  • Pacemaker procedures doubled and mean age of recipients increased over 20 years
  • ICD procedures tripled and plateaued, with stable mean age
  • Fluoroscopy time and procedure durations remained stable for both device types
  • Proportion of DDD and CRT upgrades increased, while reintervention rate due to infections stayed stable

Structured PICO

What are the changing trends in cardiac device implantation procedures in Switzerland over the last two decades?

P
Population
Patients undergoing cardiac device implantation procedures in Switzerland between January 1, 2003 and December 31, 2022, including 124,458 pacemaker and CRT procedures (mean age 77.7 years, 59.7% male) and 29,133 ICD and CRT-D procedures (mean age 63.63 years, 80.2% male).
I
Intervention
Cardiac device implantation (pacemaker, CRT, ICD, CRT-D)
O
Outcome
Device statistics and changing trends over 20 years (including procedure volume, patient age, fluoroscopy time, procedure duration, upgrades, and reintervention rates)

This 20-year national registry analysis highlights a doubling of pacemaker procedures with aging recipients and a tripling of ICD procedures that has recently plateaued in Switzerland.

Abstract

Background: The Swiss National Device Registry (SwissEPnet) provides a comprehensive database for implantation procedures. The purpose of this study was to provide an in-depth look at device statistics and changing trends over the last 20 years. Methods: The database was analyzed between January 1, 2003 and December 31, 2022. Results: During the study period, 124,458 pacemaker and cardiac resynchronization therapy (CRT) procedures (mean age: 77.7 years; 59.7% male) were performed in 73 centers while 29,133 implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy with defibrillator (CRT-D) procedures (mean age: 63.63 years; 80.2% male) were performed in 56 centers in Switzerland. While the number of pacemaker procedures has doubled in 20 years and there has been a constant increase in the mean age of patients receiving a pacemaker, the number of ICD procedures has more than tripled and recently plateaued with a mean age which has remained stable. Fluoroscopy and procedure durations remained stable over time for pacemaker and ICD procedures. Newer technologies, leadless pacemakers and CRT procedures require more fluoroscopy time, but this has also decreased over time. While regular battery changes remained stable, the proportion of DDD and CRT upgrades increased. The overall reintervention rate due to device-associated infections was stable over time. Conclusions: There was a pronounced increase in the number of pacemaker procedures in Switzerland in the last two decades and a marked increase in ICD procedures, which have plateaued recently. Overall, there is a constant increase in mean age of patients receiving a pacemaker, while the mean age of patients receiving an ICD did not change during follow up.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Molitor et al. (2025) studied this question. Pacemaker procedures doubled and ICD procedures tripled in Switzerland over 20 years; pacemaker patient age rose, ICD patient age remained stable, infections unchanged.

synapsesocial.com/papers/699a9e00482488d673cd44f1https://doi.org/10.5167/uzh-291701