PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 26, 2026Interdisciplinary Neurosurgery0 citationsOpen Access

Comparative evaluation of silicone-coated, non-coated nylon, and micro guide wire filaments for middle cerebral artery occlusion in rats: implications for reliability and reproducibility of experimental stroke models

View Full Paper
ATAbolfazl Azami TamehJMjavad amini mahabadiAAAli Atlasi

Key Points

  • This research aimed to compare the effectiveness of different occlusion threads for modeling ischemic stroke in rats.
  • Three types of threads were tested: silicone-coated nylon, non-coated nylon, and micro guide wire.
  • Male Wistar rats were assigned randomly to ensure unbiased results.
  • Ischemic stroke was induced for 1 hour followed by 23 hours of reperfusion.
  • Silicone-coated thread resulted in better artery occlusion than the other threads.
  • 70% of animals died using non-coated nylon and micro guide wire due to subarachnoid hemorrhage.
  • Triphenyltetrazolium chloride staining indicated larger infarct volumes with silicone-coated threads.

Abstract

Animal models of ischemic stroke are essential tools in studying experimental stroke. Different types of occlusion threads are used in experimental middle cerebral artery occlusion which could result in infarct size variation. In the present study, three different types of threads were used and compared with each another. Male Wistar rats were randomly and blindly assigned in three groups using heat rounded tip non silicon-coated nylon thread, commercial silicon-coated thread and micro guide wire catheter for ischemia induction. One hour ischemic stroke was followed by 23 h reperfusion. Cerebral blood flow of middle cerebral artery territory, behavioral evaluation and infarct volume calculation were done to evaluate the model. Silicon-coated thread gave a significantly more successful results than the other two threads. Around 70% of animals died by Non silicon-coated nylon thread and Micro guide wire catheter threads from subarachnoid hemorrhage. Triphenyltetrazolium chloride monohydrate staining results showed that Silicon-coated thread tended to have larger infarct volume compared to other two filaments although behavioral evaluation showed no significant different between groups. Our findings demonstrated that coating the occlusion thread with silicon provided better and more acceptable artery occlusion than nylon filament or steel guide wire catheter

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tameh et al. (2026) studied this question.

synapsesocial.com/papers/699f95951bc9fecf3dab3735https://doi.org/10.1016/j.inat.2026.102214
Ask AI
Helpful
Bookmark
Share
View Full Paper